14
Product Specifications
Stratos Bioptic Scanner/Scale Product Specifications
Parameter | Specification |
| |
|
|
| |
|
|
| |
Model 2753 Dimensions (Typical): |
|
| |
Height | 11.1 inches (28.2cm) |
| |
Length | 20 inches (50.8cm) |
| |
Width | 11.5 inches (7.1cm) |
| |
Weight: |
|
| |
Without Scale | 17.85 lbs. (8.1kg) |
| |
With Scale | 23.85 lbs. (10.8kg) |
| |
|
|
| |
Model 2752 Dimensions (Typical): |
|
| |
Height | 11.1 inches (28.2cm) |
| |
Length | 15.7 inches (39.9cm) |
| |
Width | 11.5 inches (7.1cm) |
| |
Weight: |
|
| |
Without Scale | 16.55 lbs. (7.5kg) |
| |
With Scale | 21.8 lbs. (9.9kg) |
| |
|
|
| |
Model 2751 Dimensions (Typical): |
|
| |
Height | 11.1 inches (28.2cm) |
| |
Length | 13.9 inches (35.3cm) |
| |
Width | 11.5 inches (7.11cm) |
| |
Weight: |
|
| |
Without Scale | 15.75 lbs. (7.1kg) |
| |
|
|
| |
Optical |
|
| |
Laser Scan Lines | 21,500 per second |
| |
Imager Resolution | 838 x 640 pixel array |
| |
|
|
| |
LED | 635nm + 40nm (red LED) |
| |
IEC 62471: “Exempt Risk Group” | |||
| |||
|
|
| |
Operating Wavelength |
|
| |
Illumination | 650nm + 5nm |
| |
Laser | 650nm |
| |
|
|
| |
Voltage Requirements | 12V + 10% |
| |
|
|
| |
Current Draw 12VDC @ 25°C | Operating | Standby | |
Stratos bioptic scanner only | .85A | .41A | |
Stratos bioptic scanner with LCD Video display | .93A | .41A | |
Stratos bioptic with LCD Video display, and scale with | 1A | .47A | |
single line display | |||
|
| ||
|
|
| |
Maximum Auxiliary Power |
|
| |
12V video port | .3A |
| |
Other aux ports | .5A |
| |
|
|
| |
Temperature Ranges: |
|
| |
Operating | +50F to +104F (10C to 40C) | ||
Storage | |||
|
| ||
Humidity | 5% - 95% relative humidity, | ||
|
| ||
ESD Immunity | IEC | ||
|
|
| |
Safety/Compliance |
|
| |
Laser | IEC Class 1 |
| |
LED | IEC 62471 “Exempt Risk Group” | ||
|
|
|
14 - 1