Require Coupon Code

Require Coupon Code or 2 Digit

Addenda

Require Coupon Code or 5 Digit

Addenda

Require Coupon Code, 2 Digit

Addenda, or 5 Digit Addenda

Addenda Timeout

You can set a time during which the scanner looks for an addenda. If an addenda is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-A Number System 4 Addenda Required or UPC-A Number System 5 Addenda Required. Set the length (in milliseconds) for this timeout by scanning the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 100.

Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.

Addenda Timeout

Coupon GS1 DataBar Output

If you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from the GS1 DataBar code. Scan the GS1 Output On code below to scan and output only the GS1 DataBar code data. Default = GS1 Out-

put Off.

* GS1 Output Off

9 - 34

Page 164
Image 164
Honeywell 2700 manual Coupon GS1 DataBar Output, Addenda Timeout