Redundancy

Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. If you are having difficulty reading poor quality in-store bar codes, you may wish to scan a higher Redundancy bar code below to improve the read

rate. Default = Redundancy Off.

* Redundancy Off

1X Redundancy

2X Redundancy

3X Redundancy

4X Redundancy

UPC/EAN Security

This feature allows you to increase the security when reading UPC and EAN bar codes. For lesser quality bar codes, you may

wish to increase the security settings to improve the read rate. Default = Medium.

Minimum

Low

9 - 36

Page 166
Image 166
Honeywell 2700 manual UPC/EAN Security, Redundancy