System Administrator’s Guide

Fig. 6–15. The Manage Files Dialog Box.

Save. Copies a file from the Rapid Eye unit to the operator's PC. See Backing Up an ACUIX Configuration File to a PC, step 8, above.

Delete. Select a file and click. A confirmation dialog box appears. Click Yes to remove the file from the Rapid Eye unit.. This does not remove the information from an ACUIX dome camera.

Refresh. Updates the report in the Manage Files dialog box.

Close. Closes the Manage Files dialog box.

Using LocalView

A configuration file for an ACUIX dome camera can also be saved to a Rapid Eye unit, using LocalView. See the context-sensitive Help for LocalView.

Downloading a Configuration File to an ACUIX Dome Camera

After Backing Up an ACUIX Configuration File to a PC, p. 100, you can copy that configuration to another ACUIX camera of the same make and model.

1.Run a Maintenance Session.

2.On the Serial tab, select the port to which the Intellibus device was assigned.

3.Click Discover to update the table of ACUIX dome cameras.

4.Select one ACUIX camera or many. There is a shortcut to select all of the cameras listed: click the checkbox in the Name column; see figure 6–14.

5.Click Download to Camera. A standard Windows dialog appears, showing the drives and folders available on the operator's PC.

6.Select a configuration file (*.bin) for the ACUIX dome camera.

7.Click Open. The configuration file is downloaded to the ACUIX dome camera.

Honeywell does not recommend uploading an ACUIX configuration file from one model of ACUIX dome camera to another. For example, the configuration from an ACUIX dome camera with a FCB-EX480C camera should not be uploaded to an ACUIX dome camera with a VK-S654 camera. To identify a camera, see the procedure for Identifying the Model of the Camera, next.

Document K14392V1 Rev A

101

07/07

Page 101
Image 101
Honeywell K14392V1 manual Downloading a Configuration File to an Acuix Dome Camera, Using LocalView