Configuring Other Hardware

To clear a unit’s storage

1.Using View, run a Maintenance Session.

2.On the Statistics tab, click Clear Storage. See figure 8–1, above. A password dialog box appears.

3.Either:

There is a password on the Administrator account: type that password.

There isn’t a password. Do nothing and go to the next step.

4.Click Yes. All video, audio, alarms and other data stored on the Multi-Media unit is erased. The time needed to clear storage is about fifteen (15) seconds for each gigabyte of storage.

Clearing storage cannot be stopped or reversed, even by turning the unit off.

Turning the Multi-Media unit off only suspends the process; storage continues to clear when the unit is powered again. It is an irreversible process.

Clearing a stream

A stream is the information from one camera or data device. You may need to clear one or more streams, if there is ever:

A move or transfer of a camera or unit to another location.

Some testing of a new camera, or training operator’s in PTZ use - And so on. -

To change the name of a stream

Different names can be assigned to cameras on the Video tab (see Cameras, on p. 65); the name of a customer-device is assigned on the Serial Devices tab (see Customer Data and Customer- Device Events,

on p. 143).

Preventing Users from Clearing Storage

Add or change the password to the Administrator account. The Administrator password acts as a safety, to prevent the error of triggering a “clear storage” by mistake. To set this password, see Administrator Password, on p. 176.

-and -

Right to view Statistics tab. Your Multi SA can remove the right to use and view the statistic tab from a View operator account. See Right to Use Maintenance, on p. 180.

Multi SAs who refuse to add a password to the Administrator account also remove a safeguard to prevent inadvertent use of the Clear storage feature.