Honeywell K14392V1 manual Events, Simultaneous Sessions From One Unit

Models: K14392V1

1 260
Download 260 pages 3.89 Kb
Page 149
Image 149

System Administrator’s Guide

To Enable Audio for Use Onsite, by LocalView

1.On the Audio Setup tab, add a checkmark to the box for Channel 2 (Right) Used by Site Operator for Local Audio Monitoring. The "channel 2" Enable, Record and name become unavailable; they are not needed for monitoring audio by a LocalView operator.

2.In the Channel 1 controls, add checkmarks to the Enable boxes for Talk, Listen or both, as needed.

3.You have the option of adding checkmarks to Record boxes for Talk, Listen or both, as needed. The Enabled box needs to be checked before its Record box can be.

To Disable Audio for LocalView

Using either View (or LocalView), on the Audio Setup tab, remove the checkmark in the checkbox for Channel 2 (Right) Used by ...

Multi-Media LT Audio Resources

There is only one channel of audio on Multi-Media LT units. For audio use, see the Multi-Media LT Unit Installation Instructions.

Eagle Audio

Eagle Audio is discussed in the Multi and Eagle Audio Configuration Guide, part number K9203. Please contact your Multi distributor if you need information about Eagle Audio.

Tip

Multi Audio differs from Eagle Audio, which is an optional, third party, audio interface.

Events

For Multi events, please see Events Defined, p. 187.

Simultaneous Sessions From One Unit

Table 8–7lists the number of streams available to operators. Table 8–8shows how many operators can obtain the streams that are left available. For example, on one unit, two operators could both view 16 live cameras, each. If ten operators are running Live sessions on a unit, each could view three or four cameras (either the same cameras or others), for a total of 32. For live audio, the ten connected operators could each hear the two channels of audio, and each could monitor all data streams.

Table 8–7

Stream Availability

 

Session

Video

Audio

Data

 

 

 

 

Live

32

all streams × connected users*

all streams × connected users*

Retrieval

32

16

16

 

 

 

 

* All of the unit's streams are available, to as many operators that can connect; see table 8–8.