System Administrator’s Guide

Fig. 8–13. Expanded NetPIT device on PORT 3, showing three POS devices.

Port restrictions

A PIT device cannot be assigned to the virtual port of a NetPIT.

Only one NetPIT device can be assigned to a Multi-Media port.

If a PIT or NetPIT device is assigned to "Port 1" or "Port 2", only the RS-232 interface is available. The three serial interfaces are available on Port 3 through Port 10.

The Internal Port cannot be used for a PIT or NetPIT (Network Protocol Interface Translation) device.

Multi Audio

Channels can be renamed. View operators use audio “channels” to:

Listen. A microphone at the Rapid Eye site.

Talk. Talking on one channel, or broadcasting on both.

When listening...

All sound sources are mixed at a View operator’s station, regardless of the number of sites being monitored at once. Each Rapid Eye site can send up to two channels of audio to a View operator.

Audio Hardware

Microphones, powered speakers, and so on, need to be connected to a Multi-Media unit; the operator’s PC also needs a microphone and speaker, for two-way audio, and a sound card. For more detail about audio hardware, see the Unit Installation Instructions, K14390. A PC running View requires a sound card to produce sound from the Rapid Eye site and to send sound to it.