Message

Description

Action

 

CPR SENSOR OUT OF

The CPR Sensor is not behaving

1. Force a calibration by

RANGE

properly.

either selecting

 

 

Calibrate Now from the

 

 

menus or turn the

 

 

printer off and then back

 

 

on.

 

 

 

2. If the message persists,

 

 

contact HP Support.

 

 

 

DATA RECEIVED To print

The printer received data and is

Press to continue.

last page press

waiting for a form feed. When the

 

 

 

printer receives another file, the

 

 

 

message should disappear.

 

 

 

 

 

Deleting...<JOBNAME>

The printer is currently deleting the

No action necessary.

 

stored job.

 

 

 

 

 

 

DETECTABLE SIZE IN

A tray has been loaded with paper

1. Press

for detailed

TRAY XX For help press

that is a standard size and the switch

information.

 

in the tray is set to custom.

2. Press

and to step

 

 

through instructions.

alternates with

 

 

 

DETECTABLE SIZE IN

 

 

 

TRAY XX Recommend move

 

 

 

switch to STANDARD

 

 

 

 

 

 

DISK DEVICE FAILURE

A device failure has occurred on the

1. Printing may continue

 

specified drive.

for jobs that do not

alternates with

 

require access to the

 

 

disk drive.

Ready For menus press

 

2. To clear the message,

 

turn the printer off and

 

 

then back on.

 

 

3. If the message persists,

 

 

remove and re-install

 

 

the EIO disk drive.

 

 

4. If the message persists,

 

 

replace the EIO disk

 

 

drive.

 

 

 

 

DISK FILE OPERATION

The printer received a PJL file system

1. Printing may continue.

FAILED

command that attempted to perform

2. Turn the printer off and

alternates with

an illogical operation (for example, to

then back on.

download a file to a non-existent

3. If the message

 

directory).

 

reappears, there may

Ready For menus press

 

 

be a problem with the

 

 

software application.

 

 

 

 

136

ENWW