Reference Designator

A4A3R74

A4A3R79

A4A3R80 A4A3R8 1 A4A4ClO A4A4C17 A4A4C38 A4A4C66 A4A4C70 A4A4C92 A4A4C97 A4A4C99 A4A4ClOO A4A4ClOl A4A4R3 A4A4R16 A4A4R20 A4A4R35 A4A4R40 A4A4R42 A4A4R44 A4A4R45 A4A4R60 A4A4R64 A4A4R65 A4A4R94

A4A5C9

A4A5RlO

A4A5R62

A4A5R70

A4A5R86

A4A6A2R33

A4A7C5

A4A7C12 A4A7C2 1 A4A7C30 A4A7C39 44A7C93 44A7R12

l’hble 3-3. Factory-Selected Components (continued)

Adjustmenl

Range of Values

Function of Component

Procedure

(0 or PF)

 

1.78K to 13.3 K Log fidelity

8.25K to 82.5 K Bandpass filter temperature compensation

1.0 K to 6.81 K Bandpass filter temperature compensation

1K-OPEN Bandpass filter temperature compensation

1.0to 8.2 Sets adjustment range of SYM.

180 to 270 Sets adjustment range of LC CTR.

1.0to 8.2 Sets adjustment range of SYM.

1.0to 8.2 Sets adjustment range of SYM.

180 to 270

Sets adjustment range of LC CTR.

180 to 270

Sets adjustment range of LC CTR.

180 to 270

 

4to 13

Sets adjustment range of center cap.

4to 13

Sets adjustment range of center cap.

‘4 to 13

Sets adjustment range of center cap.

0 to 9.09

Matches amplitude of LC to XTAL bandwidths.

3.16K to 8.25 K Adjusts LC filter bandwidth.

6.19K to 12.1 K Adjusts crystal filter bandwidth.

383 to 825 Matches amplitude of LC to XTAL bandwidths.

6.19K to 12.1 K Adjusts crystal filter bandwidth.

1 K to OPEN Sets level of + 10 V TC supply.

1 K to OPEN Sets level of + 10 V TC supply.

0 to 100 Adjusts bandwidth shape in 10 kHz bandwidth.

3.16 K to 8.25 K Adjusts LC filter bandwidth.

6.19K to 12.1 K Adjusts crystal filter bandwidth.

909 to 2.73 K Adjusts positive feedback.

100 K to 1M Sets adjustment range of LC amplitudes.

10

O-16

Sets adjustment range of FREQ ZERO COARSE.

111.62 K to 2.61 K Sets 18.4 MHz Local Oscillator power.

101.33 K to 3.48 K Adjusts A8dB step.

10472 to 1.62 K Adjust A4dB step.

10215 to OPEN Adjusts A2dB step.

42.2to 75.0 Adjusts level of 3 MHz output.

 

56

to 82

Centers

first pole.

7

56 to 82

Sets adjustment range of second pole P K.

7

56

to 82

Sets adjustment range of third pole P K.

7

56

to 82

Sets adjustment range of fourth pole P K.

7

56

to 82

Sets adjustment range of fifth pole P K.

7

1.5 to 12.0

Centers

first pole.

 

10.0 K to 17.8 K

Adjusts

crystal filter bandwidth.

3 - 14 Adjustments

Page 128
Image 128