8.21.4 MHz Bandwidth Filter Adjustments

22.Adjust A4A4C73 CTR to center signal on center graticule line. Adjust A4A4C65 SYM for best symmetry of signal. See Figure 3-42 for location of adjustments. If unable to adjust A4A4C65 SYM

for satisfactory signal symmetry, increase or decrease value of A4A4C66. Refer to Table 3-3 for range of values.

23.All crystal filter bypass networks are removed. Signal should be centered and symmetrical. If not, go back to step 16 and repeat adjustments.

24.Press MARKER SPEAK SEARCH] and MARKER In].

25.Key in ~FREQUENCY SPAN] 20 kHz, [REs] 3 kHz, and MARKER

[PEAK SEARCH].

26.Adjust A4A4R49 XTAL to align markers on display. MARKER A level should indicate 1.00 X. See Figure 3-42 for location of adjustment.

A4A8 LC Adjustments

27.Disconnect cable 97 (white/violet) from A4A6Jl and reconnect to A4A8Jl. Reconnect cable 89 (gray/white) to A4A6Jl.

28.Key in [-BW) 100 kHz and [FREQUENCY SPAN] 200 kHz.

29.Press [REFERENCE LEVEL) and adjust DATA knob to place signal peak two division from the top graticule line.

30.Adjust A4AW32 LC CTR and A4A8C46 LC CTR for maximum MARKER level as indicated by CRT annotation. See Figure 3-43 for location of adjustments. If unable to adjust A4A8C32 and A4AW46 LC CTR adjustments for satisfactory signal amplitude, increase or decrease value of A4AW35 and A4A8C49. Refer to ‘Iable 3-3 for range of values.

A4A8

A t t e n u a t o r BandwIdth F i l t e r

A4A8

Figure 3-43.

Location of A4A8 21.4 MHz LC Filter and Attenuation

Adjustments

31.Key in [REsj 1 MHz and @@?ZGGi] 1 MHz.

32.Press MARKER (PEAK SEARCH] and MARKER @.

3-80 Adjustments