‘Ihble l-l. Recommended Test Equipment (1 of 5)

 

 

 

 

 

 

 

 

 

 

 

Instrument

 

Critical Specifications for

 

Zecommended

Perf.

4dj.

 

 

Equipment Substitution

 

Model

Test

 

SIGNAL

 

 

 

 

 

 

 

SOURCES

 

 

 

 

 

 

 

Synthesized

 

Frequency: 10 MHz to 1500 MHz

 

HP 8340A

X

 

Sweeper

 

Output Power: + 10 dBm maximum (leveled)

 

 

 

 

 

 

 

Aging Rate: ~1 x 10mg/day

 

 

 

 

 

 

 

Spurious Signals: 135 dBc (~7 GHz)

 

 

 

 

 

 

 

125 dBc (<20 GHz)

 

 

 

 

 

 

 

Amplitude Modulation: dc to 100 kHz

 

 

 

 

 

 

 

Leveling: Internal, External Power Meter

 

 

 

 

 

Signal

 

Frequency: 20 MHz to 450 MHz

 

HP 8640B

 

 

X

Generator

SSB Phase Noise: >130 dB below carrier at

 

 

 

 

 

 

 

20 kHz away

 

 

 

 

 

 

 

Stability: ~10 ppm/lO min.

 

 

 

 

 

 

 

(HP 8340A may be substituted)

 

 

 

 

 

Frequency

 

Frequency: 200 Hz to 80 MHz

 

HP 3335A

X

X

Synthesizer

 

Stability: f 1 x lo-‘/day

 

 

 

 

 

 

 

Amplitude Range: + 13 to -86 dBm with 0.01 dB

 

 

 

 

 

 

 

resolution

 

 

 

 

 

 

 

Attenuator Accuracy: < f0.07 dB (+ 13 to -47 dBm)

 

 

 

 

 

Pulse

 

Pulse Width: 10 nsec to 250 nsec

 

HP 8116A

 

 

X

Generator

Rise and Fall Times: ~6 nsec

 

 

 

 

 

 

 

Output Level: + 2.5V

 

 

 

 

 

Function

 

Output: Sine Wave and Triangle Wave, 2Vp-p

 

HP 3312A

X

X

Generator

Range: 100 Hz to 500 kHz (Sweep Function Available)

 

 

 

 

 

Frequency

Output: 1, 2, 5, or 10 MHz

 

HP 5061B

X

X

Standard

Accuracy: <fl x 10-l’

 

 

 

 

 

 

Aging Rate: ~1 x lo-lo/day

 

 

 

 

 

 

 

 

 

 

 

 

 

G e n e r a l I n f o r m a t i o n 1 - 3