8. Frequency Response Test

49.For each input, subtract the lowest minimum level (greatest negative) from the highest maximum (least negative) measurement recorded in steps indicated. The result should not exceed 2 dB.

SIGNAL INPUT 1

100 Hz to 500 MHz (from steps 16, 25, 42, or 48)

Spec: ~2 dB

 

 

 

Overall

Maximum

 

 

dBm

-Overall

Minimum

 

 

dBm

 

 

 

 

 

Overall

Deviation

 

dBm

SIGNAL INPUT 2

100 kHz to 1.5 GHz (from steps 12 or 31)

Spec: ~2 dB

 

 

 

Overall

Maximum

 

 

dBm

-Overall

Minimum

 

 

dBm

 

 

 

 

 

Overall

Deviation

 

dBm

50.Subtract the lowest minimum level (greatest negative) from the highest maximum (least negative) measurement recorded in steps indicated. The result should not exceed 3 dB.

SIGNAL INPUT 1

100 Hz to 1.5 GHz (from steps 15, 16, 25, 42, or 48)

Spec: ~3 dB

 

 

 

Overall

Maximum

 

 

 

dBm

-Overall

Minimum

 

 

 

dBm

 

 

 

 

 

 

Overall

Deviation

 

 

dBm

2.30 P e r f o r m a n c e T e s t s