MAP 0150: Intermittent

 

Problem

Isolation

 

 

001

 

 

 

 

 

 

 

 

 

 

 

– Make

sure

that:

 

 

Ÿ

All

cables are attached

correctly.

 

Ÿ

The room

temperature is

not outside the limits [5° to 41°C (50°

Did you find a problem?

Yes No

002

Continue with Step 004.

003

Resolve the problem. Then, go to “MAP 0210: Verify Operation” on page 2

004

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is

the

fan

 

running?

 

 

 

 

 

 

 

 

 

Yes

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

005

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Are

any

of

the

LEDs

on? Check

the

LEDs on

both

sides

of

the IBM

 

2210.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

006

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Make

sure

that:

 

 

 

 

 

 

 

 

 

 

 

 

Ÿ

The

IBM

2210 is plugged into the wall outlet.

 

 

 

 

 

 

Ÿ

The

wall

outlet has the correct voltage.

 

 

 

 

 

 

Ÿ

The

line

voltage

at

the

end

of

the

power cord is corre

Did you find a problem?

Yes No

007

Replace the power supply. Then, go to “MAP 0210: Verify

Operation” on page 2-23.

008

Correct the problem. Then, go to “MAP 0210: Verify Operation” page 2-23.

009

(Step 009 continues)

Chapter 2. Problem Determination2-11

Page 33
Image 33
IBM SY27-0345-06 manual Isolation