MAP 0150: Intermittent |
| Problem | Isolation |
| |
| 001 |
|
|
|
|
|
|
|
|
|
|
| – Make | sure | that: |
| |
| Ÿ | All | cables are attached | correctly. | |
| Ÿ | The room | temperature is | not outside the limits [5° to 41°C (50° |
Did you find a problem?
Yes No
002
Continue with Step 004.
003
Resolve the problem. Then, go to “MAP 0210: Verify Operation” on page 2
004 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Is | the | fan |
| running? |
|
|
|
|
|
|
|
|
| |||
Yes |
|
| No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 005 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Are | any | of | the | LEDs | on? Check | the | LEDs on | both | sides | of | the IBM | |||
| 2210. |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| Yes |
| No |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| 006 |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Make | sure | that: |
|
|
|
|
|
| |||
|
|
|
|
|
| Ÿ | The | IBM | 2210 is plugged into the wall outlet. | |||||||
|
|
|
|
|
| Ÿ | The | wall | outlet has the correct voltage. | |||||||
|
|
|
|
|
| Ÿ | The | line | voltage | at | the | end | of | the | power cord is corre |
Did you find a problem?
Yes No
007
Replace the power supply. Then, go to “MAP 0210: Verify
Operation” on page
008
Correct the problem. Then, go to “MAP 0210: Verify Operation” page
009
(Step 009 continues)
Chapter 2. Problem