MAP 0180: Second Service

Port

Is

Not

Working

 

001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is

the

service

port

green

LED on?

 

Yes

 

No

 

 

 

 

002

Check the connection to the system board.

Is the service port seated correctly in the socket?

Yes No

003

Seat the service port in the socket firmly.

Is the problem corrected?

Yes No

004

Go to Step 007.

005

Go to “MAP 0210: Verify Operation” on page 2-23.

 

 

006

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Go

to Step

007.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

007

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Run

the

 

Extended

POST using

a

wrap plug in the service port. For assi

to

Chapter 3, “Diagnostics”

on

page 3-1.

Is the service port green LED on?

Yes No

008

Go to Step 010.

009

Problem is corrected. Go to “MAP 0210: Verify Operation” on page 2-23.

010

(Step 010 continues)

Chapter 2. Problem Determination2-15

Page 37
Image 37
IBM SY27-0345-06 manual MAP 0180 Second Service