MAP 0110: Communication Problem
001
Make sure that:
The fan is clear of any obstructions.
The room temperature is within limits (5° to 41°C [50° to 104°F])
Did you find a problem?
Yes No
002
Continue with Step 004.
003
Resolve the problem. Then, go to “MAP 0210: Verify Operation” on page 2-23.
004
Is the fan running?
Yes No
005
Replace the fan. Then, go to “MAP 0210: Verify Operation” on page 2-23.
006
Run the System Extended Diagnostics. For assistance, go to “Operational
Diagnostics” on page 3-2. If you are unable to resolve the problem, contact your
next level of support.
Chapter 2. Problem Determination 2-3