Manuals
/
Intel
/
Marine Equipment
/
Life Jacket
Intel
MB440LX
manual
Installing a Hard Disk Drive, 137
Models:
MB440LX
1
137
232
232
Download
232 pages
26.75 Kb
134
135
136
137
138
139
140
141
<
>
Specifications
Install
Error messages
Pin Signal
Password
Power Supply Fault
Controls and Indicators
Administrator
Connecting Peripheral Devices
System Configuration Options
Page 137
Image 137
1
2
OM06470
Figure
5-2.
Installing a Hard Disk Drive
M440FX Server System Product Guide
137
Page 136
Page 138
Page 137
Image 137
Page 136
Page 138
Contents
Intel MB440LX System Installation Guide
Printed on Recycled paper
Safety Guidelines
Safety Guidelines
Notational Conventions
Preface
Your Chapter Title Goes Here
Contents
Configuring The System
Installing The System
Working Inside Your System
Scsi Backplane and Drives Hot-swapping Configuring
Server Resources
Power System
System Board Jumpers
Ports and Connectors
Equipment Log
Solving Problems
Regulatory Specifications
Figures
Tables
M440LX Server System Product Guide
Contents
∙ One or two Pentium II processors
Server Description
Feature Description
System Features
Feature Description
Chassis
Server
Back/Right Side View
Peripherals
Controls and Indicators
Front Panel
Controls and Indicators
Security with the Setup utility
Security with padlocks and alarm switches
Security with the System Configuration Utility SCU
System Security
Security Padlocks
Secure Boot Mode
Password Protection
Boot Sequence Control
Boot Without Keyboard
Server Cooling
Power System
Diskette Write Protection
Video Blanking
Inch User Accessible Drive Bays
Inch User Accessible Diskette Drive Bay
Peripheral Drive Bays
Inch Hot-docking Drive Bays
ISA Expansion Slots
Onboard RAID
Server System Board
PCI Video Controller
PCI Expansion Slots
Standard VGA Modes
Video Modes
Extended VGA Modes
IDE Controller
Scsi Controllers
Baseboard Management Controller BMC does the following
Server Management
Memory Module
Pentium II Processor
Base System Configuration
System Configuration Options
System Upgrade Options
Installing The System
Selecting a Site
Environmental Specifications
Physical Specifications
After Unpacking the Server
Installing the Pentium II Processor
Installing the Memory Module
Keyboard
Connecting Peripheral Devices
Mouse
Monitor
Server I/O Panel
Turning on Your Server
Checking the Power Cords
Power and Reset Buttons
Power-on Self-Test
Creating Installation Software Diskettes
Installing The System
Configuration Utilities
Configuring The System
Power-on Self-Test
When to Use the System Configuration Utility
How to start the SCU
Memory Subsystem Group
System Board Settings Field Descriptions
Systems Group
Extended Memory Options
On-Board Disk Controllers
Onboard Communications Devices
IDE Subsystem Group
IDE Configuration Primary Master
Floppy Drive Subsystems Group
IDE Drive Options Primary Master
IDE Configuration Primary Slave
IDE Drive Options Primary Slave
Standard CHS
Boot Device Priority
Multiboot Group
KB and Mouse Subsystem Group
Console Redirection
User Password Option
Administrative Password Option
Security Subsystem
Other Security Subsystem Options
Management Subsystem Group
Scsi ROM Bios Options Group
Running the Setup Utility
When to Run the Bios Setup Utility
ESC
Press
Main Menu
IDE Submenu
Sec
Keyboard Features Submenu
30/sec
DOS
Advanced Menu
PCI Configuration Submenu
0040h
Embedded Scsi Device Submenu
Normal
Integrated Peripherals Submenu
3F8
378
2F8
Primary
Secondary
Security Menu
Administrator
Password Submenu
System Management Submenu
Server Menu
9600
Boot Menu
Console Redirection Submenu
Hard Drive Submenu
Boot Device Priority Submenu
Exit Menu
Hot Keys
Using the Symbios Scsi Utility
Running the Scsi Utility
Press these keys
Installing Scsi Drivers
Installing Video Drivers
Configuring The System
Tools and Supplies You Need
Working Inside Your System
Preparation
Removing a Side Cover
Covers
Side Covers
Replacing a Side Cover
Removing the Top Cover
Top Cover
Replacing the Top Cover
Replacing the Plastic Front Cover
Removing the Plastic Front Cover
Plastic Front Cover
Snap-in Plastic Peripheral Bay Cover
Removing the Snap-in Plastic Peripheral Bay Cover
Replacing the Snap-in Plastic Peripheral Bay Cover
Removing the Termination Board
Board Set
Removing a Termination Board
Installing a Voltage Regulator Module
Installing a Voltage Regulator Module
Installing a Pentium II Processor
Installing a Pentium II Processor
Removing a Pentium II Processor
Installing the Memory Module
Installing the Memory Module
Removing the Memory Module
Installing the RPX Module
Installing the RPX Module
Removing the RPX Module
Add-in Boards
10. Expansion Slot Cover
Installing an Add-in Board
M440LX Server System Product Guide
11. Installing an ISA Add-in Board, Component-side Up
101
12. Installing a PCI Add-in Board, Component-side Down
Removing an Add-in Board
103
Diskette Drive
Removing the Diskette Drive
13. Removing the Diskette Drive
105
Installing a Diskette Drive
Inch Peripherals
107
Installing a 5.25-inch Peripheral Device
16. Removing the EMI Shield
109
17. Snap-in Plastic Slide Rails
18. Installing a 5.25-inch Peripheral Device
111
Removing a 5.25-inch Peripheral Device
Varning
Back-up Battery
113
Replacing the Back-up Battery
19. Lithium Back-up Battery
Removing the Front Panel Board
Front Panel Board
Replacing the Front Panel Board
115
20. Removing the Front Panel Board
117
Fans
Removing a Front Panel Fan
21. Front Panel Fans
119
22. Front Fan Assembly
Replacing a Front Panel Fan
Removing the Fan Below the Top Power Supply
121
23. Fan Below the Top Power Supply
24. Rear Fan Assembly
123
Replacing the Fan Below the Power Supply
Removing a Power Supply
125
Replacing a Power Supply
Removing the Power Share Backplane
Power Share Backplane
127
26. Removing the Power Share Backplane
27. Power Share Backplane Connectors
129
Installing the Power Share Backplane
Removing a Hot-docking Backplane
Installing a Hot-docking Backplane
Scsi Hot-docking Backplane
131
28. Removing a Hot-docking Backplane
132 Working Inside Your System
Tools and Supplies You Need
Scsi Backplane and Drives Hot-swapping and Configuring
Hot-docking Bays
133
Scsi Hard Disk Drive
135
Mounting a Scsi SCA Hard Disk Drive in a Plastic Carrier
Installing a Scsi SCA Hard Disk Drive in a Hot-docking Bay
137
Installing a Hard Disk Drive
Hot-swapping a Scsi SCA Hard Disk Drive
139
Configuration Options
J10 Drive
Scsi ID Configuration Options
Internal/External INT/EXT Jumper J8
141
Changing Scsi Device ID Addresses
Scsi Backplane
Wide/Fast Scsi 16-Bit Connector
Scsi Hot-docking Backplane Connectors
Pin Signal
143
Wide/Fast SCA2 Scsi 16-Bit Connectors
145
Power Connectors
Fan Connector
Pin Name Description
Front Panel Connector
147
Server Resources
148 Server Resources
Memory Module Resources
149
Memory Module
DOS Compatibility Region
Memory Regions
Extended Memory Region
Address Range hex Amount Function
ECC Memory Banks
ECC Memory
Sample Dimm Size Combinations
151
152 Server Resources
Installing DIMMs
153
Dimm Orientation
Properly Seated Dimm
155
Removing DIMMs
Removing ECC Memory DIMMs
System Board Resources
Installing the Video Memory Dram
Video Memory Dram
Removing the Video Memory Dram
U7C1
Address Resource
Addresses and Resources
159
160 Server Resources
161
Interrupts
Flash ROM
Power System Configurations
Power System
Configuration level Redundancy Number of supplies
163
Power System Voltages +3.3V +5V +12V
Power Enable/Disable PON
Power System Control Signals
Output Power Connections
Remote Sense Connections
Connectors +12
Power Good Circuit
VA Monitor Circuit
²C Communication Circuit
Power Supply Presence Detect
Power Supply Fault
System Current Monitor
167
Power Supply to Powershare Board Connections
Power Share Backplane Interconnections
Pin Signal Color
Backplane to System Board Power Interface
Backplane to Peripheral Interface
169
Backplane to System Board Control Connections
Power Supply Input Voltages
Pin Connector Designator Description
171
Power Supply Output Voltages
Server Current Usage
Device +3.3 +12
173
Current maximum at voltage levels
Total Combined Wattage
Calculating Power Usage
Total Combined Power Used by Your System
175
Worksheet for Calculating DC Power Usage
Total Current
Current maximum at Voltage levels Device +12
177
System Board Jumpers
System Board Jumpers
Configuration Jumpers
Normal Boot
Pins default Jumper Bold Description
Chassis Intrusion Detection
179
Flash Memory
Fault Resilient Booting FRB
Updating the Bios
181
CPU Speed
Recovering the Bios
Boot Option
Beep Code Message
Password
183
Cmos
185
Ports and Connectors
Signal States
System Board Layout
System Board Layout
187
System Board Connector Locations
I2C Connector
Power Connector
Auxiliary Power Connector
189
Control Panel Connector
Diskette Drive Port
Wide/Fast 16-Bit Scsi Connector
191
IDE Connector
Scsi Controller Activity LED Connector
Fan Connectors
Blower Connectors
193
Server Management Connector
Pin Signal Description
Pin Signal
ISA Connectors
195
PCI Connectors
Mouse Keyboard Pin Signal
Keyboard and Mouse Connectors
197
Parallel Port
VGA Video Port
199
Serial Ports
200 Ports and Connectors
Resetting the Server
Solving Problems
Manually
Programmed
Initial System Startup
Checklist
203
Running New Application Software
After the System Has Been Running Correctly
205
Additional Troubleshooting Procedures
Preparing the System for Diagnostic Testing
Confirming Loading of the Operating System
Monitoring Post
Verifying Proper Operation of Key System Lights
207
Specific Problems and Corrective Actions
Power Light Does Not Light
System Cooling Fans Do Not Rotate Properly
209
No Characters Appear on Screen
Characters Are Distorted or Incorrect
Diskette Drive Activity Light Does Not Light
Incorrect or no Beep Codes
211
Hard Disk Drive Activity Light Does Not Light
Problems With Application Software
Beeps Error Message and Conditions
Error and Informational Messages
Post Beep Codes
Post Beep Codes
Normal Port-80 Codes
Post Codes and Countdown Codes
Port-80 Codes
Port 80 Code Reason
215
216 Solving Problems
217
218 Solving Problems
Post Error Codes and Messages
Post Error Codes and Messages
Code Error message
219
220 Solving Problems
221
222 Solving Problems
223
224 Solving Problems
Safety Compliance
Regulatory Specifications a
Declaration of the Manufacturer or Importer
225
CE Mark
Electromagnetic Compatibility EMC
Electromagnetic Compatibility Notice USA
Europe EN55022
227
English translation of the notice above
Electromagnetic Compatibility Notices International
229
Equipment Log B
Equipment Log
231
Equipment Log
281885-001
Top
Page
Image
Contents