Intel MB440LX manual Power System Configurations, 163

Models: MB440LX

1 232
Download 232 pages 26.75 Kb
Page 163
Image 163

Power System 7

This chapter describes the power system and explains how to calculate power consumption.

Power System Configurations

The server contains a modular power system that may be configured with one, two, or three 360 watt power supplies.

Configuration level

Redundancy

Number of supplies

Entry

Nonredundant

1

Entry

Redundant

2

Maximum

Nonredundant

2

Maximum

Redundant

3

An entry level power system typically limits the server configuration to dual processors, 1 GB memory, five hard drives, and total power dissipated. A maximum level power system provides power for fully configured servers.

Each power supply has a built-in fan and its own power cord. For servers with redundant power systems, the loss of a single power supply will not affect the operation of the server.

M440LX Server System Product Guide

163

Page 163
Image 163
Intel MB440LX manual Power System Configurations, 163, Configuration level Redundancy Number of supplies