Contents
Liebert iTRUST UPS System
Page
Contents
Page
Error! Bookmark not defined
Page
Configuration
Basics
Operation Theory
Main circuit of UPS
Structure and Layout
Components of 20/30kVA UPS
Normal mode
Operation Modes
Battery Mode
Bypass Mode
ECO Mode
Maintenance Mode
United Power Mode
Parallel Operation mode
Dual Input Mode
Specifications
Basic Functions
Functional Parameters
Parameters of Liebert iTrust UPS are given in -1
LCD+LED
Electrical Parameters
Page
Dimensions
Environmental Conditions
Unpacking
Fixing holes
40/60kVA UPS Outline Dimension
Hoisting the UPS
Transportation
Positioning of UPS
Transportatio with Forklift
Fixed position without a base
Fixed cabinet position on a base
Cable Access
Install the UPS on a support rack
Ventilation
UPS top cable output
One UPS cabinet and one battery cabinet
One UPS cabinet and several battery cabinets
Layout of Cabinet
12 Layout
Page
Selection of cables
Selection of power cables
Calculation of current of power cables
Current carrying capacity of cables
Cable connections
Selection of signal cables
Power cables
Cabling layout
Cable routing
20/30kVA UPS bottom cable output
Cable connection
Power cable connection of One branch utility source
Signal cable
Routing the signal cable
Earthing Method
Layout of signal cables of 20/30/40/60kVA UPS
Connection method
RS232 Serial Port
Connection of modem
Connection of input and output voltage free contacts
12 RS485 Port
BLV-C
Connector Name of contacts Board name Input/output
Battery Temperature detection cable
Connection of Single UPS System
Page
Startup Procedure
Explanation of Circuit Breakers
Startup
Setting the functions
Function Setup Menu
UL33-0400L 125030 Inv. On Units Out
Functional checks
Modem RS232
Switching between operation mode
Check the function of the display panel
Commissioning of UPS
Display panel
Layout of Display Panel
LED Indication
Function Dividing
Functional Keys
Menu key
Alarm Buzzer
LCD and Menu Keys
LCD
UL33-0400L 123020
Main Menu Display
Displayed information
Opening display
UPS Basic Information
Menu Keys Display Window
Display Menu
Information of main menu
Shift keyF1 display
UL33-0400L
Local Batt. Temp. C 23.2 System Batt. Boost Charging
Chinese
Function Setup
Language setup
Address setup
Time setup
UL33-0400L 125030 Inv. On Units Out
27 Setup the date
Manual battery self-test
29 Setup the date
Contrast adjustment
History log
Background communication setup
33 History log
Call-back number setup
Modem RS232
Battery low
39 Call-back number setup
Prompt window
12.5
UL33-0400L 123020 Inv. On Units Mains Power
Events and State Information
44 Load capacity exceed that of single module UPS system
UPS Events
UPS states State Reason
Setup procedures
Start up
Start from utility
Shutdown in battery mode
Shutdown in normal mode
Shutdown in bypass mode
Shutdown in ECO mode
Emergency shutdown and recovery
Shutdown in United powering mode
Transferring between operation modes
Fault clear
Mute
Monitoring system
Monitoring single UPS
Monitoring parallel operation system
Input and output contacts
Output dry contact
Input contacts
Daily maintenance
Maintenance
Temperature measuring
Daily checking
Weekly checking
Annual checking
Battery maintenance
Battery storage
Other checking
Manual battery self-test
Auto battery self test
Shutdown maintenance
Procedures
UPS system troubleshooting
LED indicator
Basics
Buzzer alarm
LED indicator of lightning protection device
LCD indication for fault information
No.1 Fault description Reason Actions to be taken
No.1 Fault description Reason Actions to be taken
UPS
Features of parallel systems
System Introduction
Conditions for parallel operation
Theory of Operation
Parallel System consisting of two units
Paralleling for Redundancy of more than two units
Paralleling for Capacity Expansion
Series Hot-Standby parallel system
Series backup mode
Operation modes
Parallel operation system with two UPS units
Installation
Cabinet installation
Parallel operation system with multi UPS units
Electrical installation
Power cables
Signal cables
External Power Distribution
Start up of Parallel Operation System
Using the Parallel Operation System
Switch on the Parallel System
Start from battery
Shutdown the Parallel Operation System
Shutdown in united operation mode
Normal mode to battery mode
Bypass mode to normal mode
Repairing the failed UPS unit in parallel operation system
Normal mode to bypass mode
Battery mode to normal mode
Emergency shutdown
Fault and Fault Process Methods
UPS
Battery
Capacity selection
Battery cabinet
External Dimensions
Installation of battery cabinet
Wiring of the batteries
Battery layout inside battery cabinet
105
Technical features
Snmp Card and the Software
Product structure and ports
Network Software
Modem
Temperature sensor TMP12Z
Level C Lightning Protection System SPD24Z
Installation procedures of SPD24Z
Introduction of SPD24Z
User
Bypass Isolation Transformer
Using and Maintenance
Maintenance
Ambient condition
Service after Sales
Abnormal Fault Handling