Chapter 3 Electrical Assembly

Table 3-4 Definitions of input/output contacts

 

Connector

 

Name of contacts

 

 

Board name

 

input/output

 

 

 

Normally

closed

contacts

for

 

BLV-C

 

output

 

 

 

battery low alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Central contacts for battery low

 

BLV-S

 

output

 

 

 

alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

open

contacts

for

 

BLV-O

 

output

 

 

 

battery low alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

closed

contacts

for

 

BAT-C

 

output

 

 

 

battery mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Central

contacts

for

battery

 

BAT-S

 

output

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J9

 

Normally

open

contacts

for

 

BAT-O

 

output

 

 

battery mode

 

 

 

 

 

 

J10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

closed

contacts

for

 

INV-C

 

output

 

J11

 

 

 

 

 

inverter mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Central

contacts

for

inverter

 

INV-S

 

output

 

 

 

mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

open

contacts

for

 

INV-O

 

output

 

 

 

inverter mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

closed

contacts

for

 

TMP-C

 

output

 

 

 

ambient over-temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Central

contacts

for

ambient

 

TMP-S

 

output

 

 

 

over-temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

open

contacts

for

 

TMP-O

 

output

 

 

 

ambient over-temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

closed

contacts

for

 

URG-C

 

output

 

 

 

emergency shutdown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Central contacts for emergency

 

URG-S

 

output

 

 

 

shutdown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

open

contacts

for

 

URG-O

 

output

 

 

 

emergency shutdown

 

 

 

 

 

J12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

closed

contacts

for

 

WRN-C

 

output

 

J13

 

 

 

 

 

common alarm

 

 

 

 

 

 

J14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Central

contacts

for

common

 

WRN-S

 

output

 

 

 

 

 

 

 

 

alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

open

contacts

for

 

WRN-O

 

output

 

 

 

common alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally

closed

contacts

for

 

OVR-C

 

output

 

 

 

overload

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33