CiM-550 IP Enabled Satellite Modem

 

 

 

 

 

 

 

Rev. 2

Remote Control

 

 

 

 

 

 

 

 

 

CD/CIM550.IOM

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

Command

 

Arguments for

 

Description of arguments

 

Response to Command

 

Query

 

Response to

Type

 

(Instruction

 

Command or

 

(note that all arguments are ASCII numeric

 

(target to controller)

 

(Instruction

 

query

 

 

Code and

 

Response to

 

codes, that is, ASCII codes between 48 and 57)

 

 

 

Code and

 

(target to

 

 

qualifier)

 

Query

 

 

 

 

 

qualifier)

 

controller)

 

 

 

 

 

 

 

 

Interval

 

 

 

 

SSI=x, where x = 0 to 9 in 10 minute steps. Note:

 

SSI* (message ok, but not

 

 

 

argument)

 

 

 

 

 

 

setting this parameter to 0 disables the statistics

 

permitted in current mode)

 

 

 

 

 

 

 

 

 

 

logging function. Example: SSI=3 means 30

 

 

 

 

 

 

 

 

 

 

 

 

minutes

 

 

 

 

 

 

Clear All

 

CAS=

 

None

Command only

 

CAS= (message ok)

 

N/A

 

N/A

Stored

 

 

 

 

 

Instructs the unit to clear all Stored Statistics

 

 

 

 

 

 

Statistics

 

 

 

 

 

This command takes no arguments.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Retrieve

 

N/A

 

75 bytes

Query only

 

N/A

 

RNE?

 

RNE={CR}ABC

next 5

 

 

 

 

 

Unit returns the oldest 5 Stored Events which have

 

 

 

 

 

ddmmyyhhmms

unread

 

 

 

 

 

not yet been read over the remote control. Reply

 

 

 

 

 

s{CR}ABCddm

Stored

 

 

 

 

 

format: {CR}Sub-body{CR}Sub-body{CR}Sub-

 

 

 

 

 

myyhhmmss{C

Events

 

 

 

 

 

body{CR}Sub-body{CR}Sub-body, where Sub-

 

 

 

 

 

R}ABCddmmyy

 

 

 

 

 

 

body=

 

 

 

 

 

hhmmss{CR}AB

 

 

 

 

 

 

ABCddmmyyhhmmss,

 

 

 

 

 

Cddmmyyhhmm

 

 

 

 

 

 

 

 

 

 

 

ss{CR}ABCddm

 

 

 

 

 

 

A being the fault/clear indicator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

myyhhmmss

 

 

 

 

 

 

F=Fault

 

 

 

 

 

(see description

 

 

 

 

 

 

C=Clear

 

 

 

 

 

for details of

 

 

 

 

 

 

I=Info

 

 

 

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B being the fault type where:

 

 

 

 

 

 

 

 

 

 

 

 

1=Unit

 

 

 

 

 

 

 

 

 

 

 

 

2=Rx Traffic

 

 

 

 

 

 

 

 

 

 

 

 

3=Tx Traffic

 

 

 

 

 

 

 

 

 

 

 

 

4=Power on/off, or log cleared

 

 

 

 

 

 

 

 

 

 

 

 

and C being the fault code, as defined under the

 

 

 

 

 

 

 

 

 

 

 

 

‘FLT’ message table entry, except Info codes,

 

 

 

 

 

 

 

 

 

 

 

 

which are: 0=power off, 1=power on, 2=log

 

 

 

 

 

 

 

 

 

 

 

 

cleared, 3=global config change, and 4=

 

 

 

 

 

 

 

 

 

 

 

 

redundancy config change. If there are no new

 

 

 

 

 

 

 

 

 

 

 

 

events, the unit replies with RNE? If there are less

 

 

 

 

 

 

75