CiM-550 IP Enabled Satellite Modem

 

 

 

 

 

 

 

Rev. 2

Remote Control

 

 

 

 

 

 

 

 

 

CD/CIM550.IOM

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

Command

 

Arguments for

 

Description of arguments

 

Response to Command

 

Query

 

Response to

Type

 

(Instruction

 

Command or

 

(note that all arguments are ASCII numeric

 

(target to controller)

 

(Instruction

 

query

 

 

Code and

 

Response to

 

codes, that is, ASCII codes between 48 and 57)

 

 

 

Code and

 

(target to

 

 

qualifier)

 

Query

 

 

 

 

 

qualifier)

 

controller)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

than 5 events to be retrieved, the remaining

 

 

 

 

 

 

 

 

 

 

 

 

positions are padded with zeros.

 

 

 

 

 

 

Retrieve

 

N/A

 

2 bytes,

 

Query only.

 

N/A

 

NUE?

NUE=xx (see

Number of

 

 

 

numerical

 

Unit returns the number of Stored Events which

 

 

 

 

 

description for

unread

 

 

 

 

 

remain unread, in the form xx. Note: This means

 

 

 

 

 

details of

Stored

 

 

 

 

 

unread over the remote control - viewing the stored

 

 

 

 

 

arguments)

Events

 

 

 

 

 

events from the front panel of the modem does not

 

 

 

 

 

 

 

 

 

 

 

 

affect this value. Example reply: NUE=98

 

 

 

 

 

 

Retrieve

 

N/A

 

130 bytes

Query only

 

N/A

 

RNS?

 

RNS={CR}AA.A

next 5

 

 

 

 

 

Unit returns the oldest 5 Stored Statistics which

 

 

 

 

 

BB.BC.CD.Ddd

unread

 

 

 

 

 

have not yet been read over the remote control.

 

 

 

 

 

mmyyhhmmss{

Stored

 

 

 

 

 

Reply format:

 

 

 

 

 

CR}AA.ABB.BC

Statistics

 

 

 

 

 

{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Su

 

 

 

 

 

.CD.Dddmmyyh

 

 

 

 

 

 

b-body{CR}Sub-body, where Sub-body=

 

 

 

 

 

hmmss{CR}AA.

 

 

 

 

 

 

AA.ABB.BC.CD.Dddmmyyhhmmss,

 

 

 

 

 

ABB.BC.CD.Dd

 

 

 

 

 

 

 

 

 

 

 

dmmyyhhmmss

 

 

 

 

 

 

AA.A = Minimum Eb/No during sample period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

{CR}AA.ABB.B

 

 

 

 

 

 

BB.B = Average Eb/No during sample period.

 

 

 

 

 

C.CD.Dddmmyy

 

 

 

 

 

 

C.C = Max. Tx Power Level Increase during

 

 

 

 

 

hhmmss{CR}AA

 

 

 

 

 

 

 

 

 

 

 

.ABB.BC.CD.Dd

 

 

 

 

 

 

sample period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dmmyyhhmmss

 

 

 

 

 

 

D.D = Average Tx Power Level Increase during

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(see description

 

 

 

 

 

 

sample period.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for details of

 

 

 

 

 

 

ddmmyyhhmmss = date/time stamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

arguments)

 

 

 

 

 

 

If there are no new events, the unit replies with

 

 

 

 

 

 

 

 

 

 

 

 

RNS? If there are less than 5 statistics to be

 

 

 

 

 

 

 

 

 

 

 

 

retrieved, the remaining positions are padded with

 

 

 

 

 

 

 

 

 

 

 

 

zeros.

 

 

 

 

 

 

Retrieve

 

N/A

 

3 bytes,

 

Query only.

 

N/A

 

NUS?

NUS=xxx (see

Number of

 

 

 

numerical

 

Unit returns the number of Stored Statistics which

 

 

 

 

 

description for

unread

 

 

 

 

 

remain unread, in the form xxx. Note: This means

 

 

 

 

 

details of

Stored

 

 

 

 

 

unread over the remote control - viewing the stored

 

 

 

 

 

arguments)

Statistics

 

 

 

 

 

events from the front panel of the modem does not

 

 

 

 

 

 

76