CiM-550 IP Enabled Satellite Modem

 

 

 

 

 

 

 

 

Rev. 2

Remote Control

 

 

 

 

 

 

 

 

 

 

 

CD/CIM550.IOM

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

Command

 

Arguments for

 

Description of arguments

 

 

Response to Command

 

Query

Response to

Type

 

(Instruction

 

Command or

 

(note that all arguments are ASCII numeric

 

 

(target to controller)

 

(Instruction

query

 

 

Code and

 

Response to

 

codes, that is, ASCII codes between 48 and 57)

 

 

 

 

Code and

(target to

 

 

qualifier)

 

Query

 

 

 

 

 

 

 

qualifier)

controller)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

= Off due to ext H/W Tx Carrier Off command

 

 

permitted in current mode)

 

 

command)

 

 

 

 

 

 

(not a valid argument when used as a command)

 

 

 

 

 

 

 

 

 

 

 

 

All other codes invalid.

 

 

 

 

 

 

 

 

 

 

 

 

Example: TXO=1 (which is Tx Carrier On)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rx

 

RFQ=

 

8 bytes

 

Command or Query.

 

 

RFQ= (message ok)

 

RFQ?

RFQ=xxx.xxxx

Frequency

 

 

 

 

 

Rx Frequency, 52 MHz to 88 MHz, (70 MHz band)

 

 

RFQ? (received ok,

 

 

(same format as

 

 

 

 

 

 

or 104 MHz to 176 MHz (140 MHz band).

 

 

but invalid arguments found)

 

 

command

 

 

 

 

 

 

Resolution = 100 Hz.

 

 

RFQ* (message ok, but not

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: RFQ=143.4567 (which is 143.4567 MHz)

 

 

permitted in current mode)

 

 

 

 

 

 

 

 

 

Note: Querying ‘Options Fitted’ (using EID?) will

 

 

 

 

 

 

 

 

 

 

 

 

indicate if the unit is 70 MHz or 140 MHz IF band

 

 

 

 

 

 

Rx Data

 

RDR=

 

8 bytes

 

Command or Query.

 

 

RDR= (message ok)

 

RDR?

RDR=xxxx.xxx

Rate

 

 

 

 

 

Rx Data rate, in bps, between 2.4 kbps and 2048

 

 

RDR? (received ok,

 

 

(same format as

 

 

 

 

 

 

kbps. Resolution = 1 bps.

 

 

but invalid arguments found)

 

 

command

 

 

 

 

 

 

Example: RDR=002.400 (which is 2.4 kbps)

 

 

RDR* (message ok, but not

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

permitted in current mode

 

 

 

Rx

 

RFT=

 

1 byte, value of

 

Command or Query.

 

 

RFT= (message ok)

 

RFT?

RFT=x

FEC Type

 

 

 

1,2,3 or 4

 

Rx FEC decoding type, where:

 

 

RFT? (received ok,

 

 

(same format as

 

 

 

 

 

0

= None (uncoded - no FEC)

 

 

but invalid argument found)

 

 

command

 

 

 

 

 

1

= Viterbi

 

 

RFT* (message ok, but not

 

 

arguments)

 

 

 

 

 

2

= Sequential

 

 

permitted in current mode)

 

 

 

 

 

 

 

 

3

= Viterbi + Reed-Solomon

 

 

 

 

 

 

 

 

 

 

 

4

= Sequential + Reed-Solomon

 

 

 

 

 

 

 

 

 

 

 

5

= Rate 3/4 QPSK Turbo (S/W Version < 1.15)

 

 

 

 

 

 

 

 

 

 

 

6

= Rate 21/44 BPSK Turbo (S/W Version > 1.14)

 

 

 

 

 

 

 

 

 

 

 

7

= Rate 5/16 BPSK Turbo (S/W Version > 1.14)

 

 

 

 

 

 

 

 

 

 

 

 

All other codes invalid.

 

 

 

 

 

 

 

 

 

 

 

 

Example: RFT=1 (which is Viterbi coding)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64