Rev. 2 | |
Installation | CD/CIM550.IOM |
The
There are no internal jumpers to configure, no interface cards to install, and no other options to install. All configuration is carried out entirely in software. The unit should first be configured locally, using the front panel keypad and display. The unit will ship with a default 64 kbps, QPSK, Rate 1/2 configuration. Please refer to the ‘FRONT PANEL OPERATION’ section for details on how to fully configure the unit for the desired operating parameters.
2.4SELECT INTERNAL IF LOOPCorrect operation of the unit may be verified rapidly, without the need for externally connected equipment. From the top level menu, select TEST, then IF LOOP (refer to the ‘FRONT PANEL OPERATION’ section) The demod should synchronize, and the green RECEIVE TRAFFIC LED should illuminate. If the unit does not pass this test, call the factory for assistance.
2.5CONNECT EXTERNAL CABLESHaving verified correct operation in IF loop, enter the desired configuration, and proceed to connect all external cables. If difficulties occur, please call the factory for assistance.
Please note that the modulator gives an output power level in the range 0 to
External cables are attached to connectors on the rear panel of the
The IEC line input connector contains the ON/OFF switch for the unit. It is also fitted with two fuses - one each for line and neutral connections (or L1, L2, where appropriate). These are contained within the body of the connector, behind a small plastic flap.
For 230 volt AC operation, use T0.5A,
14