Parameter

 

Command

 

Arguments for

 

Description of arguments

 

Response to Command

 

Query

 

Response to

Type

 

(Instruction

 

Command or

 

(note that all arguments are ASCII numeric

 

(target to controller)

 

(Instruction

 

query

 

 

Code and

 

Response to

 

codes, that is, ASCII codes between 48 and 57)

 

 

 

Code and

 

(target to

 

 

qualifier)

 

Query

 

 

 

 

 

qualifier)

 

controller)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 = do nothing 1 = generate TX alarm

 

 

 

 

 

 

 

 

 

 

 

 

b = Define action on remote demod unlock:

 

 

 

 

 

 

 

 

 

 

 

 

0 = go to nominal power 1 = go to max power

 

 

 

 

 

 

 

 

 

 

 

 

c.c = Target Eb/No value, in dB, for remote demod

 

 

 

 

 

 

 

 

 

 

 

 

d = Maximum increase in Tx Power permitted, in

 

 

 

 

 

 

 

 

 

 

 

 

dB

 

 

 

 

 

 

 

 

 

 

 

 

Example: APP= 015.67

 

 

 

 

 

 

 

 

 

 

 

 

Note: If APP is selected when Framing and/or

 

 

 

 

 

 

 

 

 

 

 

 

AUPC is disabled, APP* will be returned

 

 

 

 

 

 

Remote

 

N/A

 

4 bytes,

 

Query only. (AUPC feature)

 

N/A

 

REB?

REB=xx.x

Eb/No

 

 

 

numerical

 

Returns the value of Ebi/No of the remote demod,

 

 

 

 

 

(see description

 

 

 

 

 

 

if Framing is enabled.

 

 

 

 

 

for details of

 

 

 

 

 

 

Returns 99.9 if demod is unlocked.

 

 

 

 

 

arguments)

 

 

 

 

 

 

Returns xx.x if Framing is not enabled.

 

 

 

 

 

 

 

 

 

 

 

 

Range: between 2 and 16dB. Resolution 0.2 dB.

 

 

 

 

 

 

 

 

 

 

 

 

Example: REB=12.4 (which is Eb/No = 12.4 dB)

 

 

 

 

 

 

 

 

 

 

 

 

For values > 16.0 dB, the reply will be REB=16.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tx Power

 

N/A

 

3 bytes,

 

Query only. (AUPC feature)

 

N/A

 

PLI?

PLI=x.x

level

 

 

 

numerical

 

Returns the increase in Tx power level, in dB (from

 

 

 

 

 

(see

Increase

 

 

 

 

 

the nominal setting) due to the action of AUPC.

 

 

 

 

 

description for

 

 

 

 

 

 

Returns x.x if AUPC is not enabled.

 

 

 

 

 

details of

 

 

 

 

 

 

Example: PLI=2.3

 

 

 

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Global

 

MGC=

 

78 bytes, with

 

Command or Query. Global configuration of unit, in

 

MGC= (message ok)

 

MGC?

MGC=FFF.FFF

Configuratio

 

 

 

numerical

 

the form: FFF.FFFFDDDD.DDDGRMVSPP.PCX

 

MGC? (received ok,

 

 

 

FDDD.DDDRM

n

 

 

 

entries, fixed

 

fff.ffffdddd.dddgrmvswwctt.tbIOTZAAAAAUEEEEB

 

but invalid arguments found)

 

 

 

VSPP.PCXfff.ffff

 

 

 

 

value entries,

 

YYY.YYW, where:

 

 

 

 

 

ddd.dddrmvsww

 

 

 

 

and delimiters

 

F = Tx Frequency - same as TFQ= (8 bytes)

 

 

 

 

 

ctt.tbIOTZAAAA

 

 

 

 

 

 

D = Tx Data Rate - same as TDR= (8 bytes)

 

 

 

 

 

AUEEEEBYY

 

 

 

 

 

 

 

 

 

 

 

Y.YYW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70