Rev. 2 | |
Front Panel Menus | CD/CIM550.IOM |
| DISPLAY |
| SELECTIONS/DESCRIPTION |
|
|
|
|
|
|
| ACTIVE - If the user selects ACTIVE, then a |
| SEL | ||
|
| Receive Traffic fault will be generated whenever the | |
| ACTIVE MASKED(PRESS ENT) |
| receive circuitry senses that the buffer has either |
|
| underflowed, or overflowed. | |
|
|
| MASKED - If the user selects MASKED, no alarm |
|
| ||
|
|
| will be generated. |
|
|
|
|
| DISPLAY |
| SELECTIONS/DESCRIPTION |
|
|
|
|
|
|
| ACTIVE - If the user selects ACTIVE, then a |
| SEL | ||
|
| Transmit Traffic fault will be generated whenever | |
| ACTIVE MASKED(PRESS ENT) |
| the transmit circuitry senses that the ‘all ones’ |
|
| condition is present in the transmit data. | |
|
|
| MASKED - If the user selects MASKED, no alarm |
|
| ||
|
|
| will be generated. |
|
|
|
|
| DISPLAY |
| SELECTIONS/DESCRIPTION |
|
|
|
|
|
|
| 50 Ohms |
| SELECT IF IMPEDANCE: | ||
|
| 75 Ohms | |
| 50 OHMS 75 OHMS (ENTER) |
|
|
|
|
|
|
|
|
|
|
4.1.5.3 SELECT\TEST
| DISPLAY |
| SELECTIONS/DESCRIPTION | |
|
|
|
|
|
|
|
|
| NORM |
| TEST: NORM | |||
|
| |||
| IF2 DIG2 | I/O2 RF2 (ENT) |
| |
|
|
|
| IF LOOP |
|
|
|
| DIG LOOP |
|
|
|
| I/O LOOP |
|
|
|
|
|
NORM | (Normal) This clears any test modes or loopbacks, and places the unit |
| back into an operational state. |
|
|
(Transmit CW) This is a test mode which forces the modulator to | |
| transmit a pure carrier (unmodulated). |
41