Rev. 2 | |
SNMP interface | CD/CIM550.IOM |
13.5.1.11ODU UNIT PARAMETERS
Table
OID | Description |
|
|
| |
oduUnitMuteMode | Unit mute. Can be set to: | ||||
|
| 0 | Unmute |
| |
|
| 1 | Mute |
| |
oduUnitColdStart |
|
|
|
|
|
Unit cold start. Can be set to: | |||||
|
| 0 | Disabled |
|
|
|
| 1 | Enabled |
|
|
|
|
|
|
| |
oduUnitAutoFaultRecovery Auto fault recovery. Can be set to: | |||||
|
| 0 | Disabled |
|
|
|
| 1 | Enabled |
|
|
oduUnitExtRefFaultLogic |
|
|
|
|
|
External reference fault logic. Can be set to: | |||||
|
| 0 | Disabled |
|
|
|
| 1 | Enabled |
|
|
oduUnitRefOscAdjust | Reference oscillator adjust. Can be between 0 and 255. | ||||
oduUnitLNACurrentSource LNA current source. Can be set to: | |||||
|
| 0 | Disabled |
|
|
|
|
|
|
|
|
|
| 1 | Enabled |
|
|
oduUnitLNACurrentWindow LNA current windows. Can be set to: | |||||
|
| 20 | 20 Percent |
| |
|
|
|
|
| |
|
| 25 | 25 Percent |
| |
|
| 30 | 30 Percent |
| |
|
| 35 | 35 Percent |
| |
|
| 40 | 40 Percent |
| |
|
| 45 | 45 Percent |
| |
|
| 50 | 50 Percent |
| |
|
| 99 | Disabled |
| |
OduUnitLNAFaultLogic | LNA fault logic. Can be set to: | ||||
|
| 0 | Disabled |
| |
|
| 1 | Enabled |
|
|
oduUnitRedundancyMode | Redudancy mode. Can be set to: | ||||
|
| 0 | Manual |
| |
|
|
|
|
| |
|
| 1 | Auto |
|
|
oduUnitRedForceSwitch | Force redundant switch. Can be set to 1 (yes) to issue | ||||
| command. |
|
|
|
257