| Rev. 2 | |||||
Remote Control |
|
|
|
|
|
|
|
| CD/CIM550.IOM | |
|
|
|
|
|
|
|
|
|
| |
Parameter |
| Command |
| Arguments for | Description of arguments | Response to Command |
| Query | Response to | |
Type |
| (Instruction |
| Command or | (note that all arguments are ASCII numeric | (target to controller) |
| (Instruction | query | |
|
| Code and |
| Response to | codes, that is, ASCII codes between 48 and 57) |
|
| Code and | (target to | |
|
| qualifier) |
| Query |
|
|
|
| qualifier) | controller) |
|
|
|
|
|
|
| ||||
|
|
|
|
| Note: If the RS Codec option is not installed, and |
|
|
|
| |
|
|
|
|
| the argument 3 or 4 is used, the target will return |
|
|
|
| |
|
|
|
|
| RFT? If the Turbo Codec option is not installed, |
|
|
|
| |
|
|
|
|
| and the argument 5, 6 or 7 is used, the target will |
|
|
|
| |
|
|
|
|
| return RFT? Use EID? to query the options fitted. |
|
|
|
| |
Rx FEC |
| RCR= |
| 1 byte, value of | Command or Query. | RCR= (message ok) |
| RCR? | RCR=x | |
Code Rate |
|
|
| 1,3 or 7 | Rx FEC Code rate, where: | RCR? (received ok, |
|
| (same format as | |
|
|
|
|
| 1 | = Rate 1/2 | but invalid argument found) |
|
| command |
|
|
|
|
| 3 | = Rate 3/4 (must be set for Rate 3/4 Turbo) | RCR* (message ok, but not |
|
| argument) |
|
|
|
|
| 7 | = Rate 7/8 | permitted in current mode |
|
|
|
|
|
|
|
| 8 | = Rate 21/44 (must set for Rate 21/44 Turbo)* |
|
|
|
|
|
|
|
|
| 9 | = Rate 5/16 (must set for Rate 5/16 Turbo)* |
|
|
|
|
|
|
|
|
| All other codes invalid. |
|
|
|
| |
|
|
|
|
| Example: RCR=1 (which is Rate 1/2) |
|
|
|
| |
|
|
|
|
| * Only valid for S/W Version >1.14 |
|
|
|
| |
|
|
|
|
| As a Query, returns 0 if Uncoded is selected for |
|
|
|
| |
|
|
|
|
| FEC |
|
|
|
| |
Rx |
| RMD= |
| 1 byte, value of | Command or Query. | RMD= (message ok) |
| RMD? | RMD=x | |
Modulation |
|
|
| 1or 2 or 3 | Rx Modulation type, where: | RMD? (received ok, |
|
| (same format as | |
Type |
|
|
|
| 1 | = BPSK (must be set for Rate 21/44 or 5/16 | but invalid argument found) |
|
| command |
|
|
|
|
| Turbo) | RMD* (message ok, but not |
|
| argument) | |
|
|
|
|
| 2 | = QPSK (must be set for Rate 3/4 Turbo | permitted in current mode) |
|
|
|
|
|
|
|
| operation) |
|
|
|
| |
|
|
|
|
| 3 | = OQPSK |
|
|
|
|
|
|
|
|
| All other codes invalid. |
|
|
|
| |
|
|
|
|
| Example: RMD=1 (BPSK) |
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
Rx |
| RSI= |
| 1 byte, value of | Command or Query. | RSI= (message ok) |
| RSI? | RSI=x | |
Spectrum |
|
|
| 0 or 1 | Rx Spectrum Invert selection, where: | RSI? (received ok, |
|
| (same format as | |
Invert |
|
|
|
|
|
|
|
|
| command |
65