| Rev. 2 | |||||
Remote Control |
|
|
|
|
|
|
|
|
| CD/CIM550.IOM | |
|
|
|
|
|
|
|
|
|
|
|
|
Parameter |
| Command |
| Arguments for |
| Description of arguments |
| Response to Command |
| Query | Response to |
Type |
| (Instruction |
| Command or |
| (note that all arguments are ASCII numeric |
| (target to controller) |
| (Instruction | query |
|
| Code and |
| Response to |
| codes, that is, ASCII codes between 48 and 57) |
|
|
| Code and | (target to |
|
| qualifier) |
| Query |
|
|
|
|
| qualifier) | controller) |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| 0 = Off Line (forced into standby by 1:N or 1:1 |
|
|
|
| arguments) |
|
|
|
|
|
| Switch) 1= On Line (normal). All other codes |
|
|
|
|
|
|
|
|
|
|
| invalid. Example: RED=1 (On Line) |
|
|
|
|
|
Local/Remot |
| LRS= |
| 1 byte, value of |
| Command or query (Command only if S/W > 1.13) |
| LRS= |
| LRS? | LRS=x (see |
e Status |
|
|
| 0 or 1 |
| As a query, returns the local/remote status of the |
| (message ok) |
|
| description for |
|
|
|
|
|
| unit, where: |
|
|
|
| details of |
|
|
|
|
|
| 0 = local |
|
|
|
| arguments) |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 1= remote |
|
|
|
|
|
|
|
|
|
|
| When used as a comand, uses the same codes for |
|
|
|
|
|
|
|
|
|
|
| an argument. |
|
|
|
|
|
|
|
|
|
|
| Example: LRS=1 (unit is in remote mode) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Serial |
| SNO= |
| 4 bytes |
| Command portion is FACTORY USE ONLY. Used |
| SNO= (message ok) |
| SNO? | SNO=xxxx (see |
Number |
|
|
| numerical |
| to set or Query the units 4 digit serial number. |
|
|
|
| description for |
|
|
|
| 0000 to 9999 |
| Unit returns its S/N, in the form xxxx. |
|
|
|
| details of |
|
|
|
|
|
| Example: SNO=1765 |
|
|
|
| arguments) |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
Software |
| N/A |
| 4 bytes, |
| Query only. |
| N/A |
| SWR? | SWR=x.xx (see |
Revision |
|
|
| numerical |
| Unit returns the value of internal software revision |
|
|
|
| description for |
|
|
|
|
|
| installed in the unit, in the form x.xx |
|
|
|
| details of |
|
|
|
|
|
| Example: SWR=1.03 (Ver 1.03) |
|
|
|
| arguments) |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
Equipment |
| N/A |
| 6 bytes, |
| Query only. |
| N/A |
| EID? | EID=aaaabc |
ID |
|
|
| numerical |
| Unit returns the equipment identification, and the |
|
|
|
| (see description |
|
|
|
|
|
| options fitted, in the form aaaabc, where: |
|
|
|
| for details of |
|
|
|
|
|
| aaaa defines the Modem model number. Example: |
|
|
|
| arguments) |
|
|
|
|
|
| 2550 is |
|
|
|
|
|
|
|
|
|
|
| is |
|
|
|
|
|
|
|
|
|
|
| 4550 is |
|
|
|
|
|
|
|
|
|
|
| QPSK only - S/W Version less than 1.15) |
|
|
|
|
|
|
|
|
|
|
| 5550 is |
|
|
|
|
|
|
|
|
|
|
| QPSK, plus Rate 21/44 and Rate 5/16 BPSK) |
|
|
|
|
|