| Rev. 2 | |||||||
Remote Control |
|
|
|
|
|
|
|
|
|
|
|
| CD/CIM550.IOM | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Parameter |
| Command |
|
| Arguments for |
|
| Description of arguments |
| Response to Command |
| Query |
| Response to | |
| Type |
| (Instruction |
|
| Command or |
|
| (note that all arguments are ASCII numeric |
| (target to controller) |
| (Instruction |
| query | |
|
|
| Code and |
|
| Response to |
|
| codes, that is, ASCII codes between 48 and 57) |
|
|
| Code and |
| (target to | |
|
|
| qualifier) |
|
| Query |
|
|
|
|
|
|
| qualifier) |
| controller) |
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| b defines the IF band, with 1 = 70MHz, 2 = |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| 140MHz |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| c defines RX only, with 1 = RX/TX, 2 = RX only. |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Example: EID=455011 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Codec, 70 MHz band, RX/TX) |
|
|
|
|
|
| |
| Faults |
| N/A |
| 5 bytes, |
|
| Query only. Unit returns the current fault and status |
| N/A |
| FLT? | FLT=abcde (see | |||
| and |
|
|
|
| first 3 bytes |
|
| codes for the Unit (hardware), Tx Traffic and Rx |
|
|
|
|
| description for | |
| Status |
|
|
|
|
|
| Traffic, in the form abcde, where: |
|
|
|
|
| details of | ||
|
|
|
|
|
|
| a = Unit fault status, b = Tx Traffic status, |
|
|
|
|
| arguments | |||
|
|
|
|
|
| 4th and 5th |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| c = Rx Traffic Status, d = Change in Fault Status |
|
|
|
|
|
| ||
|
|
|
|
|
| bytes, value of 0 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| or 1 |
|
| since last poll (0 = none, 1 = change), e = Change |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| in Unit Configuration since last poll (0 = none, 1 = |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| change) |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Unit faults: |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 0 | = No faults |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 1 | = Power supply fault, 5 volts |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 2 | = Power supply fault , 12 volts |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 3 | = Power supply fault, |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 4 | = Power supply fault, 18 volts |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 5 | = Power supply fault, |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 6 | = RAM load fail |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 7 | = Tx synthesiser lock |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 8 | = Rx synthesiser |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 9 | = Power cal Checksum error |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| A = FPGA main chain load fail |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| B = Turbo FPGA load fail |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| C = CiM IP Module Fail |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Tx Traffic status: |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| 0 | = Tx traffic OK |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
79