CiM-550 IP Enabled Satellite Modem

 

 

 

 

 

 

Rev. 2

Remote Control

 

 

 

 

 

 

 

 

 

CD/CIM550.IOM

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

Command

 

Arguments for

 

Description of arguments

 

Response to Command

 

Query

Response to

Type

 

(Instruction

 

Command or

 

(note that all arguments are ASCII numeric

 

(target to controller)

 

(Instruction

query

 

 

Code and

 

Response to

 

codes, that is, ASCII codes between 48 and 57)

 

 

 

Code and

(target to

 

 

qualifier)

 

Query

 

 

 

 

 

qualifier)

controller)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G = Tx FEC Coding type - same as TFT= (1 byte)

 

 

 

 

(same format as

 

 

 

 

 

 

R = Tx FEC Code Rate - same as TCR= (1 byte)

 

 

 

 

command

 

 

 

 

 

 

M = Tx Modulation - same as TMD= (1 byte)

 

 

 

 

arguments)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V = Tx Spectrum Invert - same as TSI= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

S = Tx Scrambler State - same as TSC= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

P = Tx Power Level - same as TPL= (4 bytes)

 

 

 

 

 

 

 

 

 

 

 

C = Tx Clock Source - same as TCK= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

X = Tx Carrier Status - same as TXO= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

f = Rx Frequency - same as RFQ= (8 bytes)

 

 

 

 

 

 

 

 

 

 

 

d = Rx Data Rate - same as RDR= (8 bytes)

 

 

 

 

 

 

 

 

 

 

 

g = Rx FEC Decoding type - same as RFT= (1

 

 

 

 

 

 

 

 

 

 

 

byte)

 

 

 

 

 

 

 

 

 

 

 

r = Rx FEC Code Rate - same as RCR= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

m = Rx Modulation - same as RMD= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

v = Rx Spectrum Invert - same as RSI= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

s = Rx De-scrambler - same as RDS= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

w= Rx Sweep Width - same as RSW= (2 bytes)

 

 

 

 

 

 

 

 

 

 

 

c = Rx Clock Mode - same as RCM= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

t = Eb/No Alarm Point - same as EBA= (4 bytes)

 

 

 

 

 

 

 

 

 

 

 

b = Rx Buffer Size - same as RBS= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

I = Unit Interface Type - same as ITF= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

O =Unit Framing Mode - same as FRM= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

T = Unit Test Mode - same as TST= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

Z = Unit IF Impedance - same as IMP= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

A = Alarm Mask - same as MSK= (5 bytes)

 

 

 

 

 

 

 

 

 

 

 

U= ODU Comms - same as ODU= (1 byte)

 

 

 

 

 

 

 

 

 

 

 

E= EDMAC Slave address - same as ESA= (4

 

 

 

 

 

 

 

 

 

 

 

bytes)

 

 

 

 

 

71