CiM-550 IP Enabled Satellite Modem

Rev. 2

SNMP interface

CD/CIM550.IOM

OID

Description

 

OduUnitFaults

Used to Query the Alarm status of the CSAT. A integer

 

value will be returned between 0..262143 where the bits

 

that are set indicate the faults which have occurred:

 

 

 

 

 

 

bit 0

24 volt power supply

 

 

bit 1

20 volt power supply

 

 

bit 2

12 volt power supply

 

 

 

 

 

 

bit 3

10 volt power supply

 

 

bit 4

+5 volt power supply

 

 

bit 5

-5 volt power supply

 

 

 

 

 

 

bit 6

Tx Synthesizer Unlocked

 

 

bit 7

Tx IFLO Unlocked

 

 

bit 8

Rx Synthesizer Unlocked

 

 

bit 9

Rx IFLO Unlocked

 

 

bit 10

Reference lock detect

 

 

bit 11

LNA Current Alarm

 

 

bit 12

Fan Current Alarm

 

 

bit 13

Temperature Alarm

 

 

bit 14

HPA Thermal Shutdown Alarm

 

 

bit 15

Internal IIC Bus Alarm

 

 

bit 16

EEPROM Checksum

 

 

bit 17

NVRAM/RTC Low Battery Alarm

 

 

 

 

13.5.1.15 ODU LOGS

Table 13-49. ODU Logs OIDs

OID

Description

oduClearEventsLog

Can be set to 1 (yes) to issue command.

oduNumberUnreadEvents

CSAT returns the number of Stored Events which remain

 

unread. Value can be between 0 and 99.

oduRetrieveNext5Events

CSAT returns the oldest 5 Stored Events that have not yet

 

been read over the remote control. Reply format: Sub-

 

body{CR}Sub-body{CR}Sub-body{CR}Subbody{CR}Sub-

 

body,

 

where Sub-body=YYYYYYYYYY ZZ mmddyyhhmmss,

 

YYYYYYYYYY being the fault description.

 

ZZ being the alarm type: FT = Fault, OK = Clear, IF =

 

Information.

 

mmddyyhhmmss = date/time stamp.

261