CiM-550 IP Enabled Satellite Modem

Rev. 2

CLI and Telnet Interface

CD/CIM550.IOM

The Redundancy Configuration page contains the following options/fields:

Menu Options/Fields

Entry

Description

Current State

Read

Defines the online/offline status of the CiM.

 

Only

 

Management IP Address,

Read

IP Address for the Ethernet Interface for the Local Unit.

Local Unit

Only

The value is set through the Ethernet Interface(fei0)

 

 

page. The Management IP Address must be on the

 

 

same subnet as the other management IP and traffic IP.

Management Subnet Prefix

Read

Subnet Prefix for the Ethernet Interface for the Local

Length, Local Unit

Only

Unit. The value is set through the Ethernet

 

 

Interface(fei0) page. The Management Subnet Prefix

 

 

Length must be the same as the other management

 

 

prefix length and traffic prefix length. Enter the subnet

 

 

mask prefix length (range is 8..30).

Management IP address,

Read

IP Address for the Ethernet Interface for the Remote

Redundant Unit

Only

Unit. The value is set through the Ethernet

 

 

Interface(fei0) page on the other modem in the

 

 

redundant pair. The Management IP Address must be

 

 

on the same subnet as the other management IP and

 

 

traffic IP.

Management Subnet Prefix

Read

Subnet Prefix for the Ethernet Interface for the Local

Length, Redundant Unit

Only

Unit. The value is set through the Ethernet

 

 

Interface(fei0) page on the other modem in the

 

 

redundant pair. The Management Subnet Prefix Length

 

 

must be the same as the other management prefix

 

 

length and traffic prefix length. Enter the subnet mask

 

 

prefix length (range is 8..30).

Redundant Traffic IP

T

The Traffic IP will float between the two redundant

Address

 

modems and will always be active on the Online

 

 

Modem. The Redundant IP Traffic Address must be on

 

 

the same subnet as the other traffic IP.

 

 

Enter the ip address in aaa.bbb.ccc.ddd format

Redundant Traffic Subnet

M

The Traffic IP will float between the two redundant

Prefix Length

 

modems and will always be active on the Online

 

 

Modem. The Redundant Subnet Prefix Length must be

 

 

the same as the other traffic prefix length.

 

 

Enter the subnet mask prefix length (range is 8..30).

Force Unit Offline

F

If the modem is currently Online, this command will

 

 

force a switchover so that the redundant pair becomes

 

 

the Online modem and processes the incoming traffic.

 

 

This modem will transition from Online to Offline. Is the

 

 

modem is already Offline, then this command will be

 

 

ignored.

Save Parameters

S

This option allows a user to save the current

 

 

configuration of the CiM to permanent storage. This

 

 

configuration will be restored on each successive power

 

 

cycle of the CiM.

Exit

X

This option allows a user to exit the current menu and

 

 

return to its parent menu.

160