Rev. 2 | |
CiM IP Module Checkout & Fault Isolation | CD/CIM550.IOM |
14.2.8CIM 2 CONFIGURATION
Disconnect
14.2.8.1SETTING IP ADDRESS(ES)
Step Procedure
1 From the Main Menu select Network Configuration
2 Set Ethernet IP Address to 172.17.10.10.
3 Set Subnet Prefix Length to 24.
4 Set HDLC IP Address to 10.1.1.2.
5 Set RX – Enable/Disable and TX – Enable/Disable to Enable.
6 From Receive HDLC Channel Address menu set HDLC Addr 1 to 1 (0x0001)
The other parameters can be left to their factory default settings. At this point you should be able to ping CiM 2 from PC 2:
7ping 172.17.10.10
8ping 10.1.1.2
14.2.8.2ROUTE TABLE
Step Procedure
1From Transmitter Configuration,
2Enter 1 to configure the first route
3Enter a suitable name
4Set IP Address to 172.16.10.0
5Set Number of Subnet Bits to 24
6Enter the next hop IP address which is CiM 1’s HDLC IP Address, 10.1.1.1
14.2.8.3SAVE CONFIGURATION
Save parameters to permanent storage.
14.2.9VERIFICATION
At this point the basic configuration is over and you should be able to:
Ping PC 1 from PC 2 and vice versa Ping CiM 2 from PC 1 and vice versa Pass any other data between the 2 PCs
If Pings are not successful, refer to section 14.3, Troubleshooting IP Module.
424