CiM-550 IP Enabled Satellite Modem

Rev. 2

Front Panel Menus

CD/CIM550.IOM

4.1.5.2.5 SELECT\CONFIG\REMCONT

 

DISPLAY

 

SELECTIONS/DESCRIPTION

 

 

 

 

 

 

 

LOCAL

 

SELECT REMOTE CONTROL:

 

 

REMOTE

 

LOCAL REMOTE (PRESS ENT)

 

If LOCAL is selected then remote control will be

 

 

 

disabled. Remote monitoring is still possible.

 

 

 

If REMOTE is selected AND If the unit has not been

 

 

 

defined as an EDMAC SLAVE then the following

 

 

 

sub-menu will be displayed:

SELECT\CONFIG\REMCONT\REMOTE

 

 

 

 

 

DISPLAY

 

 

 

 

 

 

SELECTIONS/DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAUDRATE

 

 

REMOTE CONTROL: BAUDRATE

 

 

 

 

 

 

INTERFACE

 

 

INTERFACE (PRESS ENTER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EDIT LOCAL BUS BAUDRATE:

 

 

BAUDRATE screen

 

 

 

 

 

Edit the baud rate of the remote control bus,

 

 

 

19200 BAUD FORMAT 8-N-1

 

 

 

connected locally to the M&C computer.

 

 

 

 

 

 

 

 

 

 

 

 

Selections are 300, 1200, 2400, 4800, 9600

 

 

 

 

 

 

 

 

 

 

 

 

and 19200 baud are possible.

 

 

 

 

 

 

 

 

 

 

 

 

FORMAT selectionas are: 8-N-1, 7-E-2, 7-O-

 

 

 

 

 

 

 

 

 

 

 

 

2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The asynchronous character format is FIXED

 

 

 

 

 

 

 

 

 

 

 

 

at 8 data bits, 1 stop bit, no parity (8-N-1).

 

 

 

 

 

 

 

 

 

 

 

 

INTERFACE screen

 

 

 

SELECT. INTERFACE: EIA-232

 

 

 

 

 

 

 

EIA232

 

 

 

EIA485-2W

EIA485-4W (ENT)

 

 

EIA485-2W

 

 

 

 

 

 

 

 

 

 

 

 

EIA485-4W

 

 

 

 

 

 

 

 

 

 

 

 

At this point the user will be further prompted

 

 

 

 

 

 

 

 

 

 

 

 

to enter the bus address.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN EIA-232 MODE THE BUS

 

 

In EIA-232 mode the bus address is

 

 

 

 

 

 

 

fixed at 0, and this screen is

 

 

 

 

 

ADDRESS IS FIXED AT 0000

 

displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If either RS485 mode is selected, this

 

 

 

 

 

EDIT UNIT'S BUS ADDRESS:

 

 

 

 

 

 

 

screen is displayed.

 

 

 

0245

(PRESS ENTER)

 

The valid range of addresses is from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 to 9999.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

39