Serial Remote Control | CD/CIM550.IOM |
5.5.3INSTRUCTION CODE
This is a
5.5.4INSTRUCTION CODE QUALIFIER
This is a single character which further qualifies the preceding instruction code. Code Qualifiers obey the following rules:
1)From Controller to Target, the only permitted values are:
=(ASCII code 61)
?(ASCII code 63)
They have these meanings:
The ‘=’ code (controller to target) is used as the assignment operator, and is used to indicate that the parameter defined by the preceding byte should be set to the value of the argument(s) which follow it.
For example, in a message from controller to target, TFQ=070.0000 would mean ‘set the transmit frequency to 70 MHz.
The ‘?’ code (controller to target) is used as the query operator, and is used to indicate that the target should return the current value of the parameter defined by the preceding byte.
For example, in a message from controller to target, TFQ? would mean ‘return the current value of the transmit frequency.