Rev. 2 | |
Front Panel Menus | CD/CIM550.IOM |
Examples: 08.0,13.5,2.5,1.8 means:
Minimum Eb/No observed in the measurement interval = 8.0 dB
Average Eb/No observed in the measurement interval = 13.5 dB
Maximum TPLI observed in the measurement interval = 2.5 dB
Average TPLI observed in the measurement interval = 1.8 dB
LOSS,04.5,0.0,0.0 means:
There was a loss of demod lock during the measurement interval Average Eb/No observed in the measurement interval = 4.5 dB Maximum TPLI observed in the measurement interval = 0 dB
Average TPLI observed in the measurement interval = 0 dB (Which indicates no AUPC activity, or that AUPC is disabled.)
If the user selects CLEAR, the statistics log is cleared, and the user is taken directly back to the previous menu.
4.1.7.4.2 SELECT\MONIT\STATS\CONFIGURE
| DISPLAY |
| SELECTIONS/DESCRIPTION |
|
|
|
|
|
|
| The user is prompted to enter the logging interval |
| LOGGING INTERVAL:90 MINS | ||
|
| (the period of time over which the statistics will be | |
| (SET 00 TO DISABLE)(ENT) |
| measured). |
|
| The user can choose 10, 20, 30, 40, 50, 60, 70, 80, | |
|
|
| |
|
|
| or 90 minutes. |
|
| ||
|
|
|
|
4.1.7.5 SELECT\MONITOR\AUPC
| DISPLAY |
| SELECTIONS/DESCRIPTION |
|
|
|
|
|
|
| If AUPC is selected, and the modem is not in |
| FRAMING NOT ENABLED! | ||
|
| Framed mode, this menu is displayed. | |
| (PRESS ENTER) |
|
|
|
|
|
|
|
|
|
|
|
|
| If AUPC is selected, and the modem is in Framed |
| AUPC: REMOTE Eb/No=14.0dB | ||
|
| mode, this menu is displayed. The top line displays the | |
| TX POWER INCREASE=2.2dB |
| value of Eb/No of the demodulator at the distant end of |
|
| the satellite link. The Eb/No will display UNLOCK if the | |
|
|
| remote demod is unlocked. The bottom line shows |
|
| ||
|
|
| how much the AUPC system has increased the output |
|
|
| power. If AUPC is not enabled, the value of TX |
|
|
| POWER INCREASE will show as 0.0 dB. |
51