CiM-550 IP Enabled Satellite Modem

Rev. 2

CiM IP Module Checkout & Fault Isolation

CD/CIM550.IOM

14.2.1EQUIPMENT LIST

Following equipment is required:

Item

Equipment

Quantity

Comments

1

CiM-550 Modem

2

 

 

 

 

 

2

10/100baseT Ethernet Hub

2

Provided by customer

 

 

 

 

3

PC with NIC and a terminal

2

Provided by customer

 

emulation program

 

 

 

 

 

 

4

Console cable (DB-9 to RJ-11)

1

Can be procured from Comtech EF Data

 

 

 

 

5

Ethernet cables

4

Provided by customer

 

 

 

 

6

IF cables

2

Provided by customer

 

 

 

(For IF loopback only. Additional

 

 

 

equipment required for RF connectivity.)

Optional Equipment

7

Traffic Generator such as

1

Provided by customer

 

SmartBits

 

 

 

 

 

 

14.2.1EQUIPMENT SETUP

Step Procedure

1Connect each CiM to the PC via the Ethernet Hub.

2Connect the TX IF on CiM 1 to RX IF of CiM 2 and vice-versa.

3Connect the DB-9 end of the console cable to the COM1 or COM2 port of the PC and the RJ-11 end to the console port at the back of CiM 1.

4Connect CiM 1 and CiM 2 to suitable power supply and turn them ON.

14.2.2PC CONIGURATION

Step Procedure

1Set the IP address on PC 1 to 172.16.10.100, mask to 255.255.255.0 and gateway to 172.16.10.10.

2Set the IP address on PC 2 to 172.17.10.100, mask to 255.255.255.0 and gateway to 172.17.10.10.

Reboot the PCs (if required).

420