Rev. 2 | |
Serial Remote Control | CD/CIM550.IOM |
EIA 485 (full duplex) summary:
Two differential pairs - one pair for controller to target, one pair for target to controller.
5.3 EIA-232
This a much simpler configuration in which the controller device is connected directly to the target via a
Whether in
All data is transmitted in framed packets. The controller is assumed to be a PC or ASCII dumb terminal, which is in charge of the process of monitor and control. The controller is the only device which is permitted to initiate, at will, the transmission of data. Targets are only permitted to transmit when they have been specifically instructed to do so by the controller.
All bytes within a packet are printable ASCII characters, less than ASCII code 127. In this context, the Carriage Return and Line Feed characters are considered printable.
All messages from controller to target require a response (with one exception). This will be either to return data which has been requested by the controller, or to acknowledge reception of an instruction to change the configuration of the target. The exception to this is when the controller broadcasts a message (such as Set time/date) using Address 0, when the target is set to