Rev. 2 | |
CLI and Telnet Interface | CD/CIM550.IOM |
Menu Options/Fields | Entry | Description |
|
| Optionally: If the user enters a multicast address |
|
| |
|
| address, then the following parameters will be |
|
| requested: |
|
| Route MultiCast packets from Ethernet to Satellite? |
|
| [y/n] |
|
| The option allows the user to specify if multicast |
|
| packets that match the provided IP address will be |
|
| routed from the Ethernet to Satellite. “No” means that |
|
| the packets will be discarded. |
|
| Route MultiCast packets from Satellite to Ethernet? |
|
| [y/n] |
|
| The option allows the user to specify if multicast |
|
| packets that match the provided IP address will be |
|
| routed from the Satellite to Ethernet. “No” means that |
|
| the packets will be discarded. |
|
| Multicast Routes always have a subnet length of 32 |
|
| and the next hop is 0.0.0.0 because it is not applicable. |
|
| Note: The CiM does allow the specification of one and |
|
| only one default route. Destination IP = |
|
| 0.0.0.0 Subnet Length = 0 Next Hop IP = |
|
| <some next hop address> |
|
| This will cause all packets which do not match |
|
| any other route to be sent to the Next Hop IP |
|
| for further processing. |
Base | B | The Route Table menu allows the user to view up to 8 |
|
| different routes per screen. To allow editing on any of the |
|
| 1024 entries that can be defined, the user can select a |
|
| base address to control which 8 routes are displayed. For |
|
| example, if the user wants to edit Routes |
|
| Base value of 32 should be defined. |
Delete Route | D | Route Name to delete |
|
|
|
Display All | P | Displays all of the routes that are currently defined in the |
|
| system. This will include automatically generated routes |
|
| which are provided to simplify provisioning of the system. |
|
| The information displayed is: Route Name, |
|
| DestIP/SnetBits, Next Hop, and Flags |
QoS/DES | Q | Activates QoS/DES page. |
|
|
|
Downlink Mcast | Read | Read only status of Downlink Multicast (Enabled or |
| Only | Disabled). |
Save Parameters | S | This option allows a user to save the current configuration |
|
| of the CiM to permanent storage. This configuration will be |
|
| restored on each successive power cycle of the CiM. |
|
|
|
Exit | X | This option allows a user to exit the current menu and |
|
| return to its parent menu. |
136