3.4.2 Hanging on the wall

Carefully read the following imformation before attempting to hang the unit on a wall. Take note of the various limitations specified in this section. Mount the unit so that twisting, bending, or any other warping does not exceed 4 mm.

A

 

B

 

 

880

 

 

50

 

C

25

 

 

162

D

Shaded areas indicate attachment points for mounting hardware. : Thermometer (temperature measurement point)

1470

D

Operating temperature restrictions

Standard single-unit installation

Distance from wall (A)

B

C

D

Ambient temperature

 

 

 

 

 

50 mm or less

300 mm or more

300 mm or more

300 mm or more

0 °C to 35 °C

 

 

 

 

 

50 mm or more

100 mm or more

50 mm or more

50 mm or more

0 °C to 40 °C

 

 

 

 

 

Requirements when used with PDP-S55-LR speaker system

When installed as a single unit, all requirements are the same as those listed above for horizontal/ vertical, left/right reverse installations. However, the figures listed above indicate the distance between the speakers and the wall.

Note

Different temperature restrictions apply to the PDK-WM03. Refer to “4.5 Wall Mount Unit PDK-WM03” (pg. 68). For a wall-mount installation, allow adequate space (a clearance of 300 mm or more) above, below, and to each side of the panel.