Pioneer 12 technical manual Embedding in walls with no space provided behind the unit

Models: 12

1 215
Download 215 pages 34.47 Kb
Page 38
Image 38

Special Installation (Place product upright and flush, embedded in the wall)

(2) Embedding in walls with no space provided behind the unit

100 mm or

more

Attach so that the fan is on the left side when viewed from the rear.

Panting (Punching) net (numerical aperture 50 % or over)

100 mm or

more

100 mm or more

100 mm or more

50 mm or

more

Cation : Due to possible heat issues, we do not recommend installing the panel in narrow, enclosed areas.

Operating Temperature Restrictions (*1)

• Ambient temperature: 0 °C to 35 °C

*1 For this installation, set the ‘FAN CONTROL’ to ‘MAX’ as shown in “5.4.3 Adjustment and Setting in the Integrator Mode 14) Cooling Fan Control Setting” (pg. 163).