Pioneer 12 Special installation When the display is put in a box, Ambient temperature 0 C to 35 C

Models: 12

1 215
Download 215 pages 34.47 Kb
Page 31
Image 31

Special installation (When the display is put in a box)

3.4.4 When the display is put in a box

Operating this display in confined spaces is not recommended.

If the display is to be used in a confined space, observe the following conditions shown in the drawing below: A 50

B 50 C 10 D 50

Use a mesh with aperture efficiency of 50 % or more.

If hot air remains in the enclosed space, the temperature may rise causing a malfunction or fire. As a precaution, the inner wall should have sufficient heat resistance or fire resistance.

Usage temperature conditions (BOX air temperature)

Ambient temperature: 0 °C to 35 °C

: Thermometer

Outside air temperature

measuring point

(temperature measurement point)

 

 

10 mm

Exhaust side

Intake side

A

A

A 50 B 50 C 10 D 50

Rear view (the following area should be made of mesh)

A+

800 mm or more

50 mm

A+

800 mm or more

50 mm

B

 

10 mm

B

 

C

D

Mesh with aperture efficiency A+ of 50 % or more

50 mm

B+

30 mm

100 mm

or more

100 mm

or more

B+

50 mm

A+

50 mm

31

Page 31
Image 31
Pioneer 12 Special installation When the display is put in a box, Usage temperature conditions BOX air temperature