Special Installation (Hanging on the wall)

Methods of Securing: Basic methods of securing the panel to a wall are shown below. Avoid blocking or covering

areas aside from those indicated by . Before attaching the unit to fittings, double-check that the thickness and height of the fittings and the number of fixing bolts is correct.

(Also refer to “3.4.1 Mounting to fittings” (pg. 24).)

Note

Heated air is drawn from the interior of the unit by fans. Before installation, consider the heat resistance of the wall or other surface behind the unit. Exhaust temperatures can be 30 °C higher than the outside temperature.

Note

For wall-mounting, do not bundle the cables in a way that block vents.

300 mm or

more

300 mm or

more

Flush-wall installation

(distance between unit and wall

less than 50 mm)

Requirements :

Free air flow (With no obstructions within a distance of 300 mm from the unit’s sides, top and bottom)

Temperature of 0 °C to 35 °C

100 mm or more

50 mm or

more

50 mm or

more

50 mm or more

Ex.: Installation requirements when

installed in wall recess

Wall-mounted installation

(distance between unit and wall

greater than 50 mm)

Requirements :

Free air flow (With no obstructions within a distance of 300 mm from the unit) around all four sides of the unit is not necessarily required when the unit is installed at a distance of greater than 50 millimeters away from the wall.

*However, in such cases, the unit may not be placed behind a glass panel or any other obstruction which would create an enclosed space.

Temperature of 0 °C to 40 °C

Panting net

100 mm or more

100 mm or more

 

100 mm or more

100 mm or more

 

Ex.: Installation when covered with a

Panting net

Wall-embedded installation

(i.e., installation in closed space)

(distance between unit and wall

greater than 50 mm)

Requirements :

See “3.4.3 Embedding in the wall” (pg. 28) for installation requirements.

Temperature of 0 °C to 40 °C