Pioneer 12 technical manual Special Installation Hanging on the wall lengthwise

Models: 12

1 215
Download 215 pages 34.47 Kb
Page 34
Image 34

Special Installation (Hanging on the wall lengthwise)

3.4.6 Hanging on the wall lengthwise

Carefully read the following imformation before attempting to mount the unit on the wall. Observe the various limitations

specified below.

Be sure to mount the unit so that twisting, bending, or any other deformation does not exceed 4 mm.

35.8

Shaded areas indicate attachment points for mounting hardware. : Thermometer (temperature measurement point)

Attach so that the fan is on the left side when viewed from the rear.

B

1470

Avoid blocking or covering this area on the upper and lower sides.

35.8

30.4

162

25

C

 

 

 

 

 

 

 

10

D

880

 

D

 

10

A

Operating Temperature Restrictions (*1)

Distance from wall (A)

B

C

D

Ambient temperature

50 mm or more

100 mm or more

50 mm or more

50 mm or more

0 °C to 35 °C

 

 

 

 

 

*1 For this installation, set the ‘FAN CONTROL’ to ‘MAX’ as shown in “5.4.3 Adjustment and Setting in the Integrator Mode 14) Cooling Fan Control Setting” (pg. 163).

34