PMC-Sierra, Inc.

S/UNI-QUAD

DATASHEET

PM5349 S/UNI-QUAD

PMC-971239

ISSUE 6

SATURN USER NETWORK INTERFACE (155-QUAD)

 

 

 

Register 0x96: S/UNI-QUAD Channel Receive Alarm Control #1

Bit

Type

Function

Default

Bit 7

 

Unused

X

Bit 6

R/W

Reserved

0

Bit 5

R/W

Reserved

0

Bit 4

R/W

PERDIEN

0

Bit 3

R/W

PRDIEN

0

Bit 2

R/W

PAISEN

0

Bit 1

R/W

LCDEN

0

Bit 0

R/W

LOPEN

0

Register 0x97: S/UNI-QUAD Channel Receive Alarm Control #2

Bit

Type

Function

Default

Bit 7

 

Unused

X

Bit 6

R/W

SFBEREN

0

Bit 5

R/W

SDBEREN

0

Bit 4

R/W

LRDIEN

0

Bit 3

R/W

LAISEN

0

Bit 2

R/W

OOFEN

0

Bit 1

R/W

LOFEN

0

Bit 0

R/W

LOSEN

0

LOSEN, LOFEN, OOFEN, LAISEN, LRDIEN, SDBEREN, SFBEREN, LOPEN, LCDEN, PAISEN, PRDIEN, PERDIEN:

The above enable bits allow the corresponding alarm indications to be reported (Ored) into the RALRM output. When the enable bit is high, the corresponding alarm indication is combined with other alarm indications and output on RALRM. When the enable bit is low, the corresponding alarm indication does not affect the RALRM output.

Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use

173

Page 179
Image 179
PMC-Sierra PM5349 manual Perdien, Prdien, Paisen, Lopen, Sfberen, Lrdien, Laisen, Oofen, Lofen