PMC-Sierra, Inc.

S/UNI-QUAD

DATASHEET

PM5349 S/UNI-QUAD

PMC-971239

ISSUE 6

SATURN USER NETWORK INTERFACE (155-QUAD)

 

 

 

Register 0x6B: RXCP Receive Cell Counter (LSB)

Bit

Type

Function

Default

Bit 7

R

RCELL[7]

X

Bit 6

R

RCELL[6]

X

Bit 5

R

RCELL[5]

X

Bit 4

R

RCELL[4]

X

Bit 3

R

RCELL[3]

X

Bit 2

R

RCELL[2]

X

Bit 1

R

RCELL[1]

X

Bit 0

R

RCELL[0]

X

Register 0x6C: RXCP Receive Cell Counter

Bit

Type

Function

Default

Bit 7

R

RCELL[15]

X

Bit 6

R

RCELL[14]

X

Bit 5

R

RCELL[13]

X

Bit 4

R

RCELL[12]

X

Bit 3

R

RCELL[11]

X

Bit 2

R

RCELL[10]

X

Bit 1

R

RCELL[9]

X

Bit 0

R

RCELL[8]

X

Register 0x6D: RXCP Receive Cell Counter (MSB)

Bit

Type

Function

Default

Bit 7

 

Unused

X

Bit 6

 

Unused

X

Bit 5

 

Unused

X

Bit 4

 

Unused

X

Bit 3

 

Unused

X

Bit 2

R

RCELL[18]

X

Bit 1

R

RCELL[17]

X

Bit 0

R

RCELL[16]

X

RCELL[20:0]:

The RCELL[18:0] bits indicate the number of cells received and written into the receive FIFO during the last accumulation interval. Cells received and filtered due to HCS errors or Idle cell matches are not counted. The counter should be polled every second to avoid saturation. The contents of these registers are valid a maximum of 67 RCLK periods after a transfer is triggered

Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use