Option 78 — Data Terminal Ready (DTR)
Interface line pin 20 can be made true when the printer status is:
ONLINE AND BUFFER ALMOST EMPTY (READY)
OFFLINE OR BUFFER ALMOST FULL (BUSY)
In addition, the DTR interface line can be held always ON (true) or always OFF (false).
Option | Display | Configuration |
Number |
| Description |
|
|
|
.0 | 78.0 | Enable ON condition when printer is online and buffer is not full |
|
| (Ready) (default). |
|
|
|
.1
.2
.3
78.1
78.2
78.3
Enable ON condition when printer is offline or buffer is full (Busy).
Enable always ON.
Enable always OFF.
Interfaces |