Using EVFU
Once the EVFU program has been enabled and loaded, the program can be accessed by sending the appropriate channel instruction to the printer. The paper is slewed to the physical line on the form having the specified channel number assigned in the EVFU memory. This is accomplished only with the PI line held high. For a data byte to be recognized as an EVFU channel instruction, the following criteria must be met:
•PI line must be high.
•Data bit 5 must be 0 (clear).
Given these two conditions, the lower 4 bits of a byte will specify the EVFU channel number. Table
NOTE: If the
Table 6–1. EVFU Channel Assignment
First Data Byte | Second Data Byte | ||
|
|
|
|
Bit # | Channel # | Bit # | Channel # |
|
|
|
|
8 | X (don’t care) | 8 | X (don’t care) |
|
|
|
|
7 | X (don’t care) | 7 | X (don’t care) |
|
|
|
|
6 | 6 | 6 | 12 |
|
|
|
|
5 | 5 | 5 | 11 |
|
|
|
|
4 | 4 | 4 | 10 |
|
|
|
|
3 | 3 | 3 | 9 |
|
|
|
|
2 | 2 | 2 | 8 |
|
|
|
|
1 (LSB) | 1 | 1 (LSB) | 7 |
|
|
|
|
EVFU |