Control Code Sequence
The printer will not return to the previous mode when a line with a mode change is printed. The printer will always remain in the new mode until another mode is specified. Cycling the printer power will restore the default mode (Configuration Option 30); however, this mode may not be the same mode prior to power cycling.
When you include the mode change control code sequence after the number of characters (see Table
Table 7–8. Characters Per Line/Mode/Configuration Option
|
| Characters Per Line/Configuration Option |
| ||||
Mode |
| 22.1 | 22.2 | 22.3 |
| 22.4 | |
22.0 |
| ||||||
|
|
|
|
|
|
|
|
1 | 132 |
| 132 | 104 | 80 |
| 80 |
|
|
|
|
|
|
|
|
2 | 132 |
| 132 | 104 | 80 |
| 80 |
|
|
|
|
|
|
|
|
3 | 165 |
| 165 | 132 | 100 |
| 80 |
|
|
|
|
|
|
|
|
4 | 159 |
| 132 | 132 | 132 |
| 80 |
|
|
|
|
|
|
|
|
5 | 176 |
| 132 | 132 | 132 |
| 80 |
|
|
|
|
|
|
|
|
NOTE: When using Configuration Option 22.0, an automatic line feed is not inserted. The numbers given are the maximum number of characters that can fit in a line in that mode. Additional characters above the listed numbers overprint the beginning of the line; however, there is one special case. A line feed will be inserted after 176 characters in Mode 5 because that is the limit of the printer input buffer.
Programming |