Options 31–41 — Control Code Assignments
Discussion
Eleven configuration options are included in this group. When the control code assigned to a specific configuration option appears in the data stream, the printer will operate in response to the selection in that configuration option. For example, if Option 31.0 is selected and ESC ! appears in the data stream, the printer will switch to Text Dump Mode.
150B/L150B
Option | Display | Option 31 | |
Number |
| Control Code Assignment – 01 Hex | |
|
|
| |
.0 | 31.0 | Escape (ESC or SOH) sequences: ESC ! for Text Dump Mode, | |
|
| ESC P for Mode 1, and ESC R for Mode 2. (default) | |
.1 | 31.1 | Escape (ESC or SOH) sequences: ESC ! for master print mode, | |
|
| ESC P for ignored, and ESC R for ignored. | |
|
|
| |
|
| Option 32 * | |
|
| Control Code Assignment – Cedilla Character Select | |
|
|
| |
.0 | 32.0 | Extended character address 128 produces a space. | |
|
|
| |
.1 | 32.1 | Extended character address 128 produces the Cedilla character | |
|
| (Default). | |
|
| * This configuration is available only on printers equipped with | |
|
| V50.59 DCU, MCU 20.25 (or later) firmware, and primary font | |
|
| PROM | |
|
|
| |
|
| Option 33 | |
|
| Control Code Assignment | |
|
|
| |
.0 | 33.0 | Slash zero disable (default). | |
|
|
| |
.1 | 33.1 | Slash zero enable. | |
|
|
| |
|
| Option 34 | |
|
| Control Code Assignment – Alternate Printronix Plot Control | |
|
|
| |
.0 | 34.0 | Enable ESC Y, even dot centers. (default) | |
|
|
| |
.1 | 34.1 | Ignore ESC Y. | |
|
|
| |
|
| Option 35 | |
|
| Control Code Assignment – Alternate Printronix Plot Control | |
|
|
| |
.0 | 35.0 | Enable ESC Z, odd dot centers (default). | |
|
|
| |
.1 | 35.1 | Ignore ESC Z. | |
|
|
|
Configuration |